CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Risk of Mortality Following Catheter Ablation of Atrial Fibrillation Heart Failure With Mid-Range (Borderline) Ejection Fraction: Clinical Implications and Future Directions Ambulatory Inotrope Infusions in Advanced Heart Failure - A Systematic Review and Meta-Analysis The year in cardiology: heart failure: The year in cardiology 2019 Impact of the Use of Intravascular Imaging on Patients Who Underwent Orbital Atherectomy Effect of Ticagrelor Monotherapy vs Ticagrelor With Aspirin on Major Bleeding and Cardiovascular Events in Patients With Acute Coronary Syndrome: The TICO Randomized Clinical Trial Imaging- and physiology-guided percutaneous coronary intervention without contrast administration in advanced renal failure: a feasibility, safety, and outcome study How to diagnose heart failure with preserved ejection fraction: the HFA–PEFF diagnostic algorithm: a consensus recommendation from the Heart Failure Association (HFA) of the European Society of Cardiology (ESC) Safety of the Deferral of Coronary Revascularization on the Basis of Instantaneous Wave-Free Ratio and Fractional Flow Reserve Measurements in Stable Coronary Artery Disease and Acute Coronary Syndromes Initial Invasive or Conservative Strategy for Stable Coronary Disease

Clinical Trial1998 Aug;19(8):1224-31.

JOURNAL:Eur Heart J. Article Link

Treatment of calcified coronary lesions with Palmaz-Schatz stents. An intravascular ultrasound study

Hoffmann R, Mintz GS, Popma JJ et al. Keywords: calcified coronary lesions; intracoronary stents, IVUS, rotational atherectomy

ABSTRACT


AIMSTo evaluate the result of coronary stenting in calcified lesions and to find morphological and procedural factors influencing the final result.


METHODS AND RESULTS - Three hundred and twenty three native coronary artery lesions in 303 patients (197 men, mean age 63.9 +/- 11.5 years) treated with Palmaz-Schatz stents were differentiated into four groups depending on their degree of circumferential calcification as defined by intravascular ultrasound [0-90 degrees (n=120), 91-180 degrees (n=58, 181-270$ (n=71) and 271-360 degrees n=74)]. In 117 lesions rotational atherectomy was used prior to stent placement. Intravascular ultrasound and quantitative angiography were performed prior to treatment and after stent placement to measure minimal and maximal lumen diameter and lumen cross-sectional area at the lesion site and the reference segments. Acute lumen gain and eccentricity index were calculated. Although higher balloon pressures were used than in the minimally calcified lesions. the final angiographic minimal lumen diameter decreased with increasing arc of calcification (3.01 +/- 0.47, 3.04 +/- 0.43, 2.85 +/- 0.53, 2.83 +/- 0.40 mm, respectively, P=0.0320) resulting in a decrease in acute diameter gain with increasing arc of calcification (2.06 +/- 0.51, 1.91 +/- 0.46, 1.81 +/- 0.56, 1.78 +/- 0.51 mm, respectively, P=0.0067). Adjunctive rotational atherectomy prior to stent placement resulted in a greater acute diameter and a greater lumen cross-sectional area gain, coupled with less final residual stenosis than pre-treatment with balloon angioplasty.

CONCLUSION - Implantation of stents in calcified lesions results in less optimal stent expansion, especially in lesions with thick, eccentric calcific plaque layers. Use of adjunctive rotational atherectomy before stent placement may improve the procedural result.