Long-Term Durability of Transcatheter Heart Valves: Insights From Bench Testing to 25 Years Effect of Intravascular Ultrasound-Guided vs Angiography-Guided Everolimus-Eluting Stent Implantation: The IVUS-XPL Randomized Clinical Trial Six Versus 12 Months of Dual Antiplatelet Therapy After Implantation of Biodegradable Polymer Sirolimus-Eluting Stent: Randomized Substudy of the I-LOVE-IT 2 Trial Comprehensive intravascular ultrasound assessment of stent area and its impact on restenosis and adverse cardiac events in 403 patients with unprotected left main disease Rationale and design of a randomized clinical trial comparing safety and efficacy of Myval transcatheter heart valve versus contemporary transcatheter heart valves in patients with severe symptomatic aortic valve stenosis: the LANDMARK trial Twelve or 30 months of dual antiplatelet therapy after drug-eluting stents Temporal Trends in Transcatheter Aortic Valve Replacement in France: FRANCE 2 to FRANCE TAVI From Subclinical Atherosclerosis to Plaque Progression and Acute Coronary Events Association Between Functional Impairment and Medication Burden in Adults with Heart Failure Clinical applications of machine learning in the diagnosis, classification, and prediction of heart failure

Clinical Trial1998 Aug;19(8):1224-31.

JOURNAL:Eur Heart J. Article Link

Treatment of calcified coronary lesions with Palmaz-Schatz stents. An intravascular ultrasound study

Hoffmann R, Mintz GS, Popma JJ et al. Keywords: calcified coronary lesions; intracoronary stents, IVUS, rotational atherectomy

ABSTRACT


AIMSTo evaluate the result of coronary stenting in calcified lesions and to find morphological and procedural factors influencing the final result.


METHODS AND RESULTS - Three hundred and twenty three native coronary artery lesions in 303 patients (197 men, mean age 63.9 +/- 11.5 years) treated with Palmaz-Schatz stents were differentiated into four groups depending on their degree of circumferential calcification as defined by intravascular ultrasound [0-90 degrees (n=120), 91-180 degrees (n=58, 181-270$ (n=71) and 271-360 degrees n=74)]. In 117 lesions rotational atherectomy was used prior to stent placement. Intravascular ultrasound and quantitative angiography were performed prior to treatment and after stent placement to measure minimal and maximal lumen diameter and lumen cross-sectional area at the lesion site and the reference segments. Acute lumen gain and eccentricity index were calculated. Although higher balloon pressures were used than in the minimally calcified lesions. the final angiographic minimal lumen diameter decreased with increasing arc of calcification (3.01 +/- 0.47, 3.04 +/- 0.43, 2.85 +/- 0.53, 2.83 +/- 0.40 mm, respectively, P=0.0320) resulting in a decrease in acute diameter gain with increasing arc of calcification (2.06 +/- 0.51, 1.91 +/- 0.46, 1.81 +/- 0.56, 1.78 +/- 0.51 mm, respectively, P=0.0067). Adjunctive rotational atherectomy prior to stent placement resulted in a greater acute diameter and a greater lumen cross-sectional area gain, coupled with less final residual stenosis than pre-treatment with balloon angioplasty.

CONCLUSION - Implantation of stents in calcified lesions results in less optimal stent expansion, especially in lesions with thick, eccentric calcific plaque layers. Use of adjunctive rotational atherectomy before stent placement may improve the procedural result.