SCAI Expert Consensus Statement Update on Best Practices for Transradial Angiography and Intervention 2019 AHA/ACC/HRS Focused Update of the 2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society Relationship of C-reactive protein reduction to cardiovascular event reduction following treatment with canakinumab: a secondary analysis from the CANTOS randomised controlled trial Incidence, Treatment, and Outcomes of Coronary Perforation During Chronic Total Occlusion Percutaneous Coronary Intervention 2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure 2017 ACC/AHA/AAPA/ABC/ACPM/AGS/APhA /ASH/ASPC/NMA/PCNA Guideline for the Prevention, Detection, Evaluation, and Management of High Blood Pressure in Adults: Executive Summary : A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines Clinician’s Guide to Reducing Inflammation to Reduce Atherothrombotic Risk Everolimus-Eluting Bioresorbable Scaffolds Versus Everolimus-Eluting Metallic Stents

Review ArticleVolume 69, Issue 25, June 2017, Pages 3055-3066

JOURNAL:J Am Coll Cardiol. Article Link

Everolimus-Eluting Bioresorbable Scaffolds Versus Everolimus-Eluting Metallic Stents

S Sorrentino , G Giustino, GD Dangas et al Keywords: bioresorbable vascular scaffold; everolimus-eluting

ABSTRACT


Background - Recent evidence suggests that bioresorbable vascular scaffolds (BVS) are associated with an excess of thrombotic complications compared with metallic everolimus-eluting stents (EES).


Objectives - This study sought to investigate the comparative effectiveness of the Food and Drug Administration-approved BVS versus metallic EES in patients undergoing percutaneous coronary intervention at longest available follow-up.


Methods - The authors searched MEDLINE, Scopus, and web sources for randomized trials comparing BVS and EES. The primary efficacy and safety endpoints were target lesion failure and definite or probable stent thrombosis, respectively.


Results - Seven trials were included: in sum, 5,583 patients were randomized to receive either the study BVS (n = 3,261) or the EES (n = 2,322). Median time of follow-up was 2 years (range 2 to 3 years). Compared with metallic EES, risk of target lesion failure (9.6% vs. 7.2%; absolute risk difference: +2.4%; risk ratio: 1.32; 95% confidence interval: 1.10 to 1.59; number needed to harm: 41; p = 0.003; I2 = 0%) and stent thrombosis (2.4% vs. 0.7%; absolute risk difference: +1.7%; risk ratio: 3.15; 95% confidence interval: 1.87 to 5.30; number needed to harm: 60; p < 0.0001; I2 = 0%) were both significantly higher with BVS. There were no significant differences in all-cause or cardiovascular mortality between groups. The increased risk for ST associated with BVS was concordant across the early (<30 days), late (30 days to 1 year), and very late (>1 year) periods (pinteraction = 0.49).


Conclusions - Compared with metallic EES, the BVS appears to be associated with both lower efficacy and higher thrombotic risk over time. (Bioresorbable vascular scaffold compare to everolimus stents in long term follow up; CRD42017059993).