CBS 2019
CBSMD教育中心
中 文

IVUS Guidance

Abstract

Recommended Article

Use of IVUS guided coronary stenting with drug eluting stent: a systematic review and meta-analysis of randomized controlled clinical trials and high quality observational studies Comparison of inhospital mortality, length of hospitalization, costs, and vascular complications of percutaneous coronary interventions guided by ultrasound versus angiography Impact of post-intervention minimal stent area on 9-month follow-up patency of paclitaxel-eluting stents: an integrated intravascular ultrasound analysis from the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials Intravascular Ultrasound-Derived Virtual Fractional Flow Reserve for the Assessment of Myocardial Ischemia Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial Intravascular Ultrasound Guidance Is Associated With Better Outcome in Patients Undergoing Unprotected Left Main Coronary Artery Stenting Compared With Angiography Guidance Alone Correlations between fractional flow reserve and intravascular ultrasound in patients with an ambiguous left main coronary artery stenosis Contribution of stent underexpansion to recurrence after sirolimus-eluting stent implantation for in-stent restenosis

Review ArticleJuly 27, 2017

JOURNAL:Oncotarget. Article Link

Intravascular ultrasound guidance in drug-eluting stents implantation: a meta-analysis and trial sequential analysis of randomized controlled trials

Qian C, Feng H, Cao J et al. Keywords: intravascular ultrasound, drug-eluting stents, meta-analysis, trial sequential analysis, randomized controlled trials

META-ANALYSIS

OBJECTIVES - Previous evidence suggested that intravascular ultrasound (IVUS) guidance could improve outcomes after drug-eluting stents (DES) placement, largely driven by data from observational studies. We, therefore, performed a meta-analysis and trial sequential analysis of randomized controlled trials to overcome this limitation.


RESULTS -  The retrieval process yielded 7 RCTs with 3,192 patients. Compared to the angiography guidance, IVUS-guided DES implantation was associated with a significant reduction in the major adverse cardiac events (MACE) (OR 0.60, 95% CI 0.46-0.78; P < 0.001), target vessel revascularization (OR 0.60, 95% CI 0.40-0.91; P = 0.02) and target lesion revascularization (OR 0.60, 95% CI 0.42-0.85; P = 0.004). IVUS and conventional angiography guidance showed similar incidence of stent thrombosis (ST) (OR 0.56, 95% CI 0.25-1.23; P = 0.15), cardiac death (OR 0.47, 95% CI 0.19-1.15; P = 0.10) and myocardial infarction (OR 0.85, 95% CI 0.45-1.61; P = 0.62). Trial sequential analysis revealed a definite reduction in MACE with IVUS guidance without solid evidence for ST.


MATERIALS AND METHODS - A systematical literature search was performed in the databases of PubMed, the Cochrane Library and ClinicalTrials.gov, complemented with reference screening from relevant articles. Primary endpoints were MACE and ST.


CONCLUSIONS - IVUS-guided DES implantation is associated with a lower risk of MACE and revascularization without conclusive benefits for ST.