CBS 2019
CBSMD教育中心
中 文

IVUS Guidance

Abstract

Recommended Article

Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance Comparison of intravascular ultrasound guided versus angiography guided drug eluting stent implantation: a systematic review and meta-analysis The impact of intravascular ultrasound guidance during drug eluting stent implantation on angiographic outcomes Usefulness of minimum stent cross sectional area as a predictor of angiographic restenosis after primary percutaneous coronary intervention in acute myocardial infarction (from the HORIZONS-AMI Trial IVUS substudy) Intravascular ultrasound-guided implantation of drug-eluting stents to improve outcome: a meta-analysis Prospective application of pre-defined intravascular ultrasound criteria for assessment of intermediate left main coronary artery lesions results from the multicenter LITRO study Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study Atherosclerotic plaque with ultrasonic attenuation affects coronary reflow and infarct size in patients with acute coronary syndrome: an intravascular ultrasound study

Review Article2016 Aug 1;216:133-9.

JOURNAL:Int J Cardiol. Article Link

Intravascular ultrasound-guided drug-eluting stent implantation: An updated meta-analysis of randomized control trials and observational studies

Steinvil A, Zhang YJ, Garcia-Garcia HM et al. Keywords: Angiography; Drug-eluting stent; Intravascular ultrasound; Meta-analysis

ABSTRACT


The use of intravascular ultrasound (IVUS) guidance for drug-eluting stent (DES) optimization is limited by the number of adequately powered randomized control trials (RCTs). We performed an updated meta-analysis, including data from recently published RCTs and observational studies, by reviewing the literature in Medline and the Cochrane Library to identify studies that compared clinical outcomes between IVUS-guided and angiography-guided DES implantation from January 1995 to January 2016. This meta-analysis included 25 eligible studies, including 31,283 patients, of whom 3192 patients were enrolled in 7 RCTs. In an analysis of all 25 studies, the summary results for all the events analyzed were significantly in favor of IVUS-guided DES implantation [major adverse cardiac events (MACE, odds ratio [OR] 0.76, 95% confidence intervals [CI]: 0.70-0.82, P<0.001); death (OR 0.62, 95% CI: 0.54-0.72, P<0.001); myocardial infarction (OR 0.67, 95% CI: 0.56-0.80, P<0.001); stent thrombosis (OR 0.58, 95% CI: 0.47-0.73, P<0.001); target lesion revascularization (TLR, OR 0.77, 95% CI: 0.67-0.89, P=0.005); target vessel revascularization (TVR, OR 0.85, 95% CI: 0.76-0.95, P<0.001)]. However, in a separate analysis of RCTs, a favorable result for IVUS-guided DES implantation was found only for MACE (OR 0.66, 95% CI: 0.52-0.84, P=0.001), TLR (OR 0.61, 95% CI: 0.43-0.87, P=0.006), and TVR (OR 0.61, 95% CI: 0.41-0.90, P=0.013). IVUS-guided percutaneous coronary intervention was associated with better overall clinical outcomes than angiography-guided DES implantation. However, in a solely RCT meta-analysis, this benefit was mainly driven by reduced rates of revascularizations.