CBS 2019
CBSMD教育中心
中 文

IVUS Guidance

Abstract

Recommended Article

Impact of intravascular ultrasound guidance on long-term mortality in stenting for unprotected left main coronary artery stenosis Meta-analysis of outcomes after intravascular ultrasound-guided versus angiography-guided drug-eluting stent implantation in 26,503 patients enrolled in three randomized trials and 14 observational studies Effects of Intravascular Ultrasound-Guided Versus Angiography-Guided New-Generation Drug-Eluting Stent Implantation: Meta-Analysis With Individual Patient-Level Data From 2,345 Randomized Patients Comparison of paclitaxel-eluting stents (Taxus) and everolimus-eluting stents (Xience) in left main coronary artery disease with 3 years follow-up (from the ESTROFA-LM registry) Novel predictor of target vessel revascularization after coronary stent implantation: Intraluminal intensity of blood speckle on intravascular ultrasound Intravascular ultrasound-derived minimal lumen area criteria for functionally significant left main coronary artery stenosis Defining a new standard for IVUS optimized drug eluting stent implantation: the PRAVIO study A three-vessel virtual histology intravascular ultrasound analysis of frequency and distribution of thin-cap fibroatheromas in patients with acute coronary syndrome or stable angina pectoris

Original Research2013 Mar 15;111(6):829-35.

JOURNAL:Am J Cardiol. Article Link

Differential prognostic effect of intravascular ultrasound use according to implanted stent length

Ahn JM, Han S, Park YK et al. Keywords: IVUS guided PCI; DES; outcome; stent length

ABSTRACT


It is unknown whether the use of intravascular ultrasound (IVUS) guidance during percutaneous coronary intervention can attenuate the stent length effect on clinical outcomes. The aim of the present study was to determine the differential prognostic effect of IVUS according to the implanted stent length. We enrolled 3,244 consecutive patients from the Interventional Cardiology Research In-cooperation Society-Drug-Eluting Stents (IRIS-DES) registry who had undergone single or overlapping stent implantation. The primary end point was major adverse cardiac events (MACE; a composite of death, myocardial infarction, and target vessel revascularization). The study population was divided by the tertiles of implanted stent length and IVUS usage. IVUS use was at the discretion of the operator. After adjusting for significant covariates, the stent length was significantly associated with the risk of MACE in the no-IVUS group (hazard ratio 1.13, 95% confidence interval 1.01 to 1.28, p = 0.042) but not in the IVUS group (hazard ratio 1.08, 95% confidence interval 0.97 to 1.20, p = 0.16). In addition, in patients with an implanted stent length of ≤22 mm (n = 998), the risk of MACE was not significantly different between the IVUS group and the no-IVUS group (hazard ratio 1.06, 95% confidence interval 0.50 to 2.28, p = 0.88). In contrast, in patients with a longer implanted stent length, the risk of MACE was significantly lower in the IVUS group than in the no-IVUS group (hazard ratio 0.47, 95% confidence interval 0.24 to 0.92, p = 0.027 for 23 to 32 mm, n = 1,109; hazard ratio 0.57, 95% confidence interval 0.33 to 0.98, p = 0.042 for ≥33 mm, n = 1,137). In conclusion, IVUS usage can attenuate the detrimental effect of the increase in the implanted stent length, supporting IVUS usage, particularly during percutaneous coronary intervention with long stent implantation.