CBS 2019
CBSMD教育中心
中 文

IVUS Guidance

Abstract

Recommended Article

Impact of plaque components on no-reflow phenomenon after stent deployment in patients with acute coronary syndrome: a virtual histology-intravascular ultrasound analysis The Role of Vascular Imaging in Guiding Routine Percutaneous Coronary Interventions: A Meta-Analysis of Bare Metal Stent and Drug-Eluting Stent Trials Percutaneous Coronary Intervention for Vulnerable Coronary Atherosclerotic Plaque Consensus from the 5th European Bifurcation Club meeting Prospective application of pre-defined intravascular ultrasound criteria for assessment of intermediate left main coronary artery lesions results from the multicenter LITRO study Intravascular Ultrasound Guidance vs. Angiographic Guidance in Primary Percutaneous Coronary Intervention for ST-Segment Elevation Myocardial Infarction - Long-Term Clinical Outcomes From the CREDO-Kyoto AMI Registry American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents Assessment of coronary atherosclerosis by IVUS and IVUS-based imaging modalities: progression and regression studies, tissue composition and beyond

Original Research2014 Aug;174(8):1360-6.

JOURNAL:JAMA Intern Med. Article Link

Long-term survival in patients undergoing percutaneous interventions with or without intracoronary pressure wire guidance or intracoronary ultrasonographic imaging: a large cohort study

Fröhlich GM, Redwood S, Rakhit R et al. Keywords: IVUS guided PCI; FFR; DES; outcome; cohort

ABSTRACT



IMPORTANCE - Intracoronary pressure wire-derived measurements of fractional flow reserve (FFR) and intravascular ultrasonography (IVUS) provide functional and anatomical information that can be used to guide coronary stent implantation. Although these devices are widely used and recommended by guidelines, limited data exist about their effect on clinical end points.


OBJECTIVE - To determine the effect on long-term survival of using FFR and IVUS during percutaneous coronary intervention (PCI).


DESIGN AND SETTING - Cohort study based on the pan-London (United Kingdom) PCI registry. In total, 64,232 patients are included in this registry covering the London, England, area.


PARTICIPANTS - All patients (n = 41,688) who underwent elective or urgent PCI in National Health Service hospitals in London between January 1, 2004, and July 31, 2011, were included. Patients with ST-segment elevation myocardial infarction (n = 11,370) were excluded.


INTERVENTIONS - Patients underwent PCI guided by angiography (visual lesion assessment) alone, PCI guided by FFR, or IVUS-guided PCI.


MAIN OUTCOMES AND MEASURES - The primary end point was all-cause mortality at a median of 3.3 years.


RESULTS - Fractional flow reserve was used in 2767 patients (6.6%) and IVUS was used in 1831 patients (4.4%). No difference in mortality was observed between patients who underwent angiography-guided PCI compared with patients who underwent FFR-guided PCI (hazard ratio, 0.88; 95% CI, 0.67-1.16; P = .37). Patients who underwent IVUS had a slightly higher adjusted mortality (hazard ratio, 1.39; 95% CI, 1.09-1.78; P = .009) compared with patients who underwent angiography-guided PCI. However, this difference was no longer statistically significant in a propensity score-based analysis (hazard ratio, 1.33; 95% CI, 0.85-2.09; P = .25). The mean (SD) number of implanted stents was lower in the FFR group (1.1 [1.2] stents) compared with the IVUS group (1.6 [1.3]) and the angiography-guided group (1.7 [1.1]) (P < .001).


CONCLUSIONS AND RELEVANCE - In this large observational study, FFR-guided PCI and IVUS-guided PCI were not associated with improved long-term survival compared with standard angiography-guided PCI. The use of FFR was associated with the implantation of fewer stents.