Recommended Article

Plaque composition by intravascular ultrasound and distal embolization after percutaneous coronary intervention Comparison of intravascular ultrasound guided versus angiography guided drug eluting stent implantation: a systematic review and meta-analysis Effect of Intravascular Ultrasound-Guided vs Angiography-Guided Everolimus-Eluting Stent Implantation: The IVUS-XPL Randomized Clinical Trial Imaging- and physiology-guided percutaneous coronary intervention without contrast administration in advanced renal failure: a feasibility, safety, and outcome study Outcomes with intravascular ultrasound-guided stent implantation: a meta-analysis of randomized trials in the era of drug-eluting stents Use of Intravascular Ultrasound Imaging in Percutaneous Coronary Intervention to Treat Left Main Coronary Artery Disease Clinical impact of intravascular ultrasound guidance in drug-eluting stent implantation for unprotected left main coronary disease: pooled analysis at the patient-level of 4 registries Atherosclerotic plaque with ultrasonic attenuation affects coronary reflow and infarct size in patients with acute coronary syndrome: an intravascular ultrasound study

Original Research2019 Feb 15;93(S1):772-778.

JOURNAL:Catheter Cardiovasc Interv. Article Link

Optical coherence tomography and intravascular ultrasound assessment of the anatomic size and wall thickness of a muscle bridge segment

Ye Z, Lai Y, Yao Y et al. Keywords: coronary perforation; myocardial bridging

ABSTRACT


OBJECTIVE - To use optical coherence tomography (OCT) and intravascular ultrasound (IVUS) in assessing myocardial bridging (MB) vessel size and wall thickness.

 

BACKGROUND - During stent implantation, MB is associated with complications, especially perforation.

 

METHODS - OCT and IVUS were performed in 56 patients with typical angiographic "milking" from November 2016 to May 2017. The vessel area and thickness in the MB segments and adjacent proximal and distal reference segments were measured and compared with eight normal left anterior descending (LAD) segment (no atherosclerosis in a segment that was at least 20 mm long and that began ~40 mm distal to the LAD ostium).

 

RESULTS - Compared with the reference vessel size distal to the MB segment (6.3 ± 1.8 mm2 ), the IVUS-measured size of the tunneled vessel during diastole was significantly smaller (6.0 ± 1.9 mm2 , p < 0.05) (remodeling index = 0.79 ± 0.18). The minimum intramyocardial arterial wall thickness was 0.16 ± 0.02 mm, significantly thinner than that of the mean reference (0.22 ± 0.03 mm, p < 0.001). The location of the thinnest arterial wall was in the distal and middle MB segments in 45 (80.4%) and 11 (19.6%) patients, respectively, and was not related to the degree of systolic compression or remodeling index. The walls of the middle and distal MB subsegments, but not of the proximal MB subsegment, were thinner than that of the comparison group of normal LADs.

 

CONCLUSION - The coronary vessel involved in an MB is both smaller and thinner than that of the adjacent non-MB segment. This may explain the increased frequency and severity of coronary perforation during stent implantation.

 