CBS 2019
CBSMD教育中心
中 文

IVUS Guidance

Abstract

Recommended Article

Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study Usefulness of intravascular ultrasound to predict outcomes in short-length lesions treated with drug-eluting stents Intravascular Ultrasound Guidance Reduces Cardiac Death and Coronary Revascularization in Patients Undergoing Drug-Eluting Stent Implantation: Results From a Meta-Analysis of 9 Randomized Trials and 4724 Patients The impact of intravascular ultrasound guidance during drug eluting stent implantation on angiographic outcomes Comprehensive intravascular ultrasound assessment of stent area and its impact on restenosis and adverse cardiac events in 403 patients with unprotected left main disease Differential prognostic effect of intravascular ultrasound use according to implanted stent length In vivo intravascular ultrasound-derived thin-cap fibroatheroma detection using ultrasound radiofrequency data analysis Clinical impact of PCSK9 inhibitor on stabilization and regression of lipid-rich coronary plaques: a near-infrared spectroscopy study

Original ResearchFebruary 2019, Volume 35, Issue 2, pp 239–247

JOURNAL:Int J Cardiovasc Imaging Article Link

Intravascular Ultrasound Guidance Reduces Cardiac Death and Coronary Revascularization in Patients Undergoing Drug-Eluting Stent Implantation: Results From a Meta-Analysis of 9 Randomized Trials and 4724 Patients

XF Gao, ZM Wang, F Wang et al. Keywords: angiography; drug-eluting stents; intravascular ultrasound; meta-analysis; optimal criteria

ABSTRACT


Intravascular ultrasound (IVUS) guidance is not routinely performed in real-word clinical practice partly because the benefit of IVUS guidance is not well established. This updated meta-analysis aims to compare IVUS-guided and angiography-guided drug-eluting stent (DES) implantation, simultaneously stressing the value of an optimal IVUS-defined procedure. Medline, Scopus, Google Scholar, and Cochrane Controlled Trials Registry were searched for the randomized trials comparing IVUS-guided and angiography-guided DES implantation. Nine eligible randomized trials including 4,724 patients were identified. At a mean follow-up of 16.7 months, IVUS guidance was associated with a significant lower risk of major adverse cardiovascular events (MACE) [5.4% vs. 9.0%; relative risks (RR): 0.61, 95% confident interval (CI) 0.49–0.74, p < 0.001], cardiac death (0.6% vs. 1.2%; RR: 0.49, 95% CI 0.26–0.92, p = 0.03), target vessel revascularization (3.5% vs 6.1%; RR: 0.58, 95% CI 0.42–0.80, p = 0.001), target lesion revascularization (3.1% vs. 5.2%; RR: 0.59, 95% CI 0.44–0.80, p = 0.001), and definite/probable stent thrombosis (0.5% vs .1.1%; RR: 0.45, 95% CI 0.23–0.87, p = 0.02) compared with angiography guidance. No significant differences in all cause death and myocardial infarction were noted between the two groups. Subgroup analysis showed that patients who met the optimal criteria had a lower rate of MACE than those with IVUS-defined suboptimal procedure (RR: 0.33, 95% CI 0.06–0.60, p = 0.02). The present meta-analysis with the largest sample size to date demonstrates that IVUS-guided DES implantation significantly reduces cardiac death, coronary revascularization and stent thrombosis, particularly for patients with IVUS-defined optimal procedures compared with angiography guidance.