Impact of intravascular ultrasound guidance on long-term mortality in stenting for unprotected left main coronary artery stenosis Meta-analysis of outcomes after intravascular ultrasound-guided versus angiography-guided drug-eluting stent implantation in 26,503 patients enrolled in three randomized trials and 14 observational studies Effects of Intravascular Ultrasound-Guided Versus Angiography-Guided New-Generation Drug-Eluting Stent Implantation: Meta-Analysis With Individual Patient-Level Data From 2,345 Randomized Patients Comparison of paclitaxel-eluting stents (Taxus) and everolimus-eluting stents (Xience) in left main coronary artery disease with 3 years follow-up (from the ESTROFA-LM registry) Novel predictor of target vessel revascularization after coronary stent implantation: Intraluminal intensity of blood speckle on intravascular ultrasound Intravascular ultrasound-derived minimal lumen area criteria for functionally significant left main coronary artery stenosis A three-vessel virtual histology intravascular ultrasound analysis of frequency and distribution of thin-cap fibroatheromas in patients with acute coronary syndrome or stable angina pectoris Defining a new standard for IVUS optimized drug eluting stent implantation: the PRAVIO study

Clinical Trial2014 Nov;7(11):1287-93.

JOURNAL:JACC Cardiovasc Interv. Article Link

Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial

Mariani J Jr, Guedes C, Lemos PA et al. Keywords: contrast; coronary intravascular ultrasound; renal failure; stent

ABSTRACT


OBJECTIVES - The aim of this study was to evaluate the impact of intravascular ultrasound (IVUS) guidance on the final volume of contrast agent used in patients undergoing percutaneous coronary intervention (PCI).


BACKGROUND - To date, few approaches have been described to reduce the final dose of contrast agent in PCIs. We hypothesized that IVUS might serve as an alternative imaging tool to angiography in many steps during PCI, thereby reducing the use of iodine contrast.

METHODS - A total of 83 patients were randomized to angiography-guided PCI or IVUS-guided PCI; both groups were treated according to a pre-defined meticulous procedural strategy. The primary endpoint was the total volume contrast agent used during PCI. Patients were followed clinically for an average of 4 months.

RESULTS - The median total volume of contrast was 64.5 ml (interquartile range [IQR]: 42.8 to 97.0 ml; minimum, 19 ml; maximum, 170 ml) in the angiography-guided group versus 20.0 ml (IQR: 12.5 to 30.0 ml; minimum, 3 ml; maximum, 54 ml) in the IVUS-guided group (p < 0.001). Similarly, the median volume of contrast/creatinine clearance ratio was significantly lower among patients treated with IVUS-guided PCI (1.0 [IQR: 0.6 to 1.9] vs. 0.4 [IQR: 0.2 to 0.6, respectively; p < 0.001). In-hospital and 4-month outcomes were not different between patients randomized to angiography-guided and IVUS-guided PCI.

CONCLUSIONS - Thoughtful and extensive use of IVUS as the primary imaging tool to guide PCI is safe and markedly reduces the volume of iodine contrast compared with angiography-alone guidance. The use of IVUS should be considered for patients at high risk of contrast-induced acute kidney injury or volume overload undergoing coronary angioplasty. (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy [MOZART]; NCT01947335).

Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.