CBS 2019
CBSMD教育中心
中 文

血管内超声指导

Abstract

Recommended Article

Intravascular ultrasound-guided systematic two-stent techniques for coronary bifurcation lesions and reduced late stent thrombosis Clinical use of intracoronary imaging. Part 1: guidance and optimization of coronary interventions. An expert consensus document of the European Association of Percutaneous Cardiovascular Interventions: Endorsed by the Chinese Society of Cardiology Catastrophic catheter-induced coronary artery vasospasm successfully rescued using intravascular ultrasound imaging guidance Attenuated plaque detected by intravascular ultrasound: clinical, angiographic, and morphologic features and post-percutaneous coronary intervention complications in patients with acute coronary syndromes Effect of Intravascular Ultrasound-Guided Drug-Eluting Stent Implantation: Five-Year Follow-Up of the IVUS-XPL Randomized Trial The Role of Vascular Imaging in Guiding Routine Percutaneous Coronary Interventions: A Meta-Analysis of Bare Metal Stent and Drug-Eluting Stent Trials Effect of Intravascular Ultrasound-Guided vs Angiography-Guided Everolimus-Eluting Stent Implantation: The IVUS-XPL Randomized Clinical Trial Intravascular ultrasound findings of early stent thrombosis after primary percutaneous intervention in acute myocardial infarction: a Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) substudy

Clinical Trial2018 Jul 6.[Epub ahead of print]

JOURNAL:Int J Cardiovasc Imaging. Article Link

Intravascular ultrasound-guided drug-eluting stent implantation is associated with improved clinical outcomes in patients with unstable angina and complex coronary artery true bifurcation lesions

Chen L, Xu T, Chen SL et al. Keywords: Coronary artery bifurcation lesions; Intravascular ultrasound guidance; Long-term follow-up; Major adverse cardiac event; Stent expansion

ABSTRACT


Stenting coronary artery bifurcation lesion is associated with suboptimal clinical results. Clinical improvement by intravascular ultrasound (IVUS) guided bifurcation stenting is controversial because small-side-branch (SB), low-risk patients and false bifurcations were included in previous studies that had no exact IVUS criteria for optimal stent expansion. We sought determine whether IVUS guidance is superior to angiography guidance for patients with true and complex bifurcation lesions. Between July 2006 and July 2012, 1465 patients with unstable angina and Medina 1,1,1 or 0,1,1 coronary bifurcation lesions were prospectively studied. 310 patients in the IVUS guidance (defined as stent symmetry index > 0.7, stent expansion index > 0.9, well apposition, and no Type B/C dissection) group were paired with 620 patients in the angiography group by propensity score-matching. The primary endpoint was the rate of composite major adverse cardiac events (MACE) (cardiac death, myocardial infarction (MI), or clinically-driven target vessel revascularization) at 1-year and at the end of study after indexed procedure. Use of IVUS guidance was mainly driven by stenting technique selection and identification of lesions' specificities. IVUS criteria for optimal stent expansion were achieved in 82.9% of patients which contribute to IVUS group data assessment and the rest did not meet optimal criteria. MACE occurred in 10.0% of patients at 1-year follow-up and 15.2% at the 7-year follow-up in the IVUS group, significantly different from 15.0% (p = 0.036) and 22.4% (p = 0.01) in the angiography group, respectively. Compared to angiography guidance, IVUS guidance also resulted in a lower 7-year cardiac death rate (6.5 versus 1.3%, p = 0.002) and MI (8.4 versus 2.3%, P < 0.001). Any revascularization was also statistically lower in the IVUS group through whole study period, compared to the angiography group. Lower MACE rates were observed in IVUS guidance group in a 7-year follow-up compared with angiography guidance alone.