CBS 2019
CBSMD教育中心
中 文

血管内超声指导

Abstract

Recommended Article

Clinical impact of intravascular ultrasound guidance in drug-eluting stent implantation for unprotected left main coronary disease: pooled analysis at the patient-level of 4 registries Role of Proximal Optimization Technique Guided by Intravascular Ultrasound on Stent Expansion, Stent Symmetry Index, and Side-Branch Hemodynamics in Patients With Coronary Bifurcation Lesions Tissue characterisation of atherosclerotic plaque in the left main: an in vivo intravascular ultrasound radiofrequency data analysis Imaging- and physiology-guided percutaneous coronary intervention without contrast administration in advanced renal failure: a feasibility, safety, and outcome study Optical Frequency Domain Imaging Versus Intravascular Ultrasound in Percutaneous Coronary Intervention (OPINION Trial) Results From the OPINION Imaging Study Plaque composition by intravascular ultrasound and distal embolization after percutaneous coronary intervention Incidence and Clinical Outcomes of Stent Fractures on the Basis of 6,555 Patients and 16,482 Drug-Eluting Stents From 4 Centers A Randomized Study of Distal Filter Protection Versus Conventional Treatment During Percutaneous Coronary Intervention in Patients With Attenuated Plaque Identified by Intravascular Ultrasound

Clinical Case StudyJune 2017, Volume 33, Issue 6, pp 807–813

JOURNAL:Int J Cardiovasc Imaging. Article Link

Intravascular ultrasound guidance of percutaneous coronary intervention in ostial chronic total occlusions: a description of the technique and procedural results

Ryan N1, Gonzalo N, Escaned J et al. Keywords: Chronic total occlusion; Intravascular ultrasound; Percutaneous coronary intervention

ABSTRACT

Inability to cross the lesion with a guidewire is the most common reason for failure in percutaneousrevascularization (PCI) of chronic total occlusions (CTOs). An ostial or stumpless CTO is an acknowledged challenge for CTO recanalization due to difficulty in successful wiring. IVUS imaging provides the opportunity to visualize the occluded vessel and to aid guidewire advancement. We review the value of this technique in a single-centre experience of CTO PCI. This series involves 22 patients who underwent CTO-PCI using IVUS guidance for stumpless CTO wiring at our institution. CTO operators with extensive IVUS experience in non-CTO cases carried out all procedures. Procedural and outcome data was prospectively entered into the institutional database and a retrospective analysis of clinical, angiographic and technical data performed. 17 (77%) of the 22 procedures were successful. The mean age was 59.8 ± 11.5 years, and 90.9% were male. The most commonly attempted lesions were located in the left anterior descending 36.4% (Soon et al. in J Intervent Cardiol 20(5):359-366, 2007) and Circumflex artery (LCx) 31.8% (Mollet et al. in Am J Cardiol 95(2):240-243, 2005). Mean JCTO score was 3.09 ± 0.75 (3.06 ± 0.68, 3.17 ± 0.98 in the successful and failed groups respectively p = 0.35). The mean contrast volume was 378.7 ml ± 114.7 (389.9 ml ± 130.5, 349.2 ml ± 52.2 p = 0.3 in the successful and failed groups respectively). There was no death, coronary artery bypass grafting or myocardial infarction requiring intervention in this series. When the success rates were analyzed taking into account the date of adoption of this technique, the learning curve had no significant impact on CTO-PCI success. This series describes a good success rate in IVUS guided stumpless wiring of CTOs in consecutive patients with this complex anatomical scenario.