CBS 2019
CBSMD教育中心
中 文

Acute Coronary Syndrom

Abstract

Recommended Article

Effect of Lipoprotein (a) Levels on Long-term Cardiovascular Outcomes in Patients with Myocardial Infarction with Nonobstructive Coronary Arteries Effects of clopidogrel vs. prasugrel vs. ticagrelor on endothelial function, inflammatory parameters, and platelet function in patients with acute coronary syndrome undergoing coronary artery stenting: a randomized, blinded, parallel study Late Survival Benefit of Percutaneous Coronary Intervention Compared With Medical Therapy in Patients With Coronary Chronic Total Occlusion: A 10-Year Follow-Up Study Chronic Kidney Disease and Coronary Artery Disease Percutaneous Support Devices for Percutaneous Coronary Intervention Cardiac Troponin Composition Characterization after Non ST-Elevation Myocardial Infarction: Relation with Culprit Artery, Ischemic Time Window, and Severity of Injury Global Chronic Total Occlusion Crossing Algorithm: JACC State-of-the-Art Review 2021 AHA/ACC/ASE/CHEST/SAEM/SCCT/SCMR Guideline for the Evaluation and Diagnosis of Chest Pain: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines

Clinical Trial2019 Jan 15;139(3):337-346.

JOURNAL:Circulation. Article Link

Unloading the Left Ventricle Before Reperfusion in Patients With Anterior ST-Segment-Elevation Myocardial Infarction

Kapur NK, Alkhouli MA, DeMartini TJ et al. Keywords: heart failure; heart ventricles; heart-assist devices; myocardial infarction; reperfusion injury; door-to-balloon time

ABSTRACT


BACKGROUND - In ST-segment-elevation myocardial infarction (STEMI), infarct size correlates directly with heart failure and mortality. Preclinical testing has shown that, in comparison with reperfusion alone, mechanically unloading the left ventricle (LV) before reperfusion reduces infarct size and that 30 minutes of unloading activates a cardioprotective program that limits reperfusion injury. The DTU-STEMI pilot trial (Door-To-Unload in STEMI Pilot Trial) represents the first exploratory study testing whether LV unloading and delayed reperfusion in patients with STEMI without cardiogenic shock is safe and feasible.


METHODS - In a multicenter, prospective, randomized exploratory safety and feasibility trial, we assigned 50 patients with anterior STEMI to LV unloading by using the Impella CP followed by immediate reperfusion (U-IR) versus delayed reperfusion after 30 minutes of unloading (U-DR). The primary safety outcome was a composite of major adverse cardiovascular and cerebrovascular events at 30 days. Efficacy parameters included the assessment of infarct size by using cardiac magnetic resonance imaging.


RESULTS - All patients completed the U-IR (n=25) or U-DR (n=25) protocols with respective mean door-to-balloon times of 72 versus 97 minutes. Major adverse cardiovascular and cerebrovascular event rates were not statistically different between the U-IR versus U-DR groups (8% versus 12%, respectively, P=0.99). In comparison with the U-IR group, delaying reperfusion in the U-DR group did not affect 30-day mean infarct size measured as a percentage of LV mass (15±12% versus 13±11%, U-IR versus U-DR, P=0.53).


CONCLUSIONS - We report that LV unloading using the Impella CP device with a 30-minute delay before reperfusion is feasible within a relatively short time period in anterior STEMI. The DTU-STEMI pilot trial did not identify prohibitive safety signals that would preclude proceeding to a larger pivotal study of LV unloading before reperfusion. An appropriately powered pivotal trial comparing LV unloading before reperfusion to the current standard of care is required.


CLINICAL TRIAL REGISTRATION - URL: https://www.clinicaltrials.gov . Unique identifier: NCT03000270.