Red Cell Distribution Width in Patients with Diabetes and Myocardial Infarction: an analysis from the EXAMINE trial Use of Mechanical Circulatory Support Devices Among Patients With Acute Myocardial Infarction Complicated by Cardiogenic Shock Letter by Jiang et al Regarding Article, “Direct Comparison of Cardiac Myosin-Binding Protein C With Cardiac Troponins for the Early Diagnosis of Acute Myocardial Infarction” Optimum Blood Pressure in Patients With Shock After Acute Myocardial Infarction and Cardiac Arrest Association of Parenteral Anticoagulation Therapy With Outcomes in Chinese Patients Undergoing Percutaneous Coronary Intervention for Non-ST-Segment Elevation Acute Coronary Syndrome Effect of Smoking on Outcomes of Primary PCI in Patients With STEMI Deficiency of GATA3-Positive Macrophages Improves Cardiac Function Following Myocardial Infarction or Pressure Overload Hypertrophy Association Between Collateral Circulation and Myocardial Viability Evaluated by Cardiac Magnetic Resonance Imaging in Patients With Coronary Artery Chronic Total Occlusion

Original ResearchVolume 74, Issue 4, July 2019

JOURNAL:J Am Coll Cardiol. Article Link

Outcome of Applying the ESC 0/1-hour Algorithm in Patients With Suspected Myocardial Infarction

R Twerenbold, JP Costabel, T Nestelberger et al. Keywords: 0/1-h algorithm; acute myocardial infarction; high-sensitivity cardiac troponin; outcome; rule-out; safety

ABSTRACT


BACKGROUND - The European Society of Cardiology (ESC) recommends the 0/1-h algorithm for rapid triage of patients with suspected nonST-segment elevation myocardial infarction (MI). However, its impact on patient management and safety when routinely applied is unknown.

 

OBJECTIVES - This study sought to determine these important real-world outcome data.

 

METHODS - In a prospective international study enrolling patients presenting with acute chest discomfort to the emergency department (ED), the authors assessed the real-world performance of the ESC 0/1-h algorithm using high-sensitivity cardiac troponin T embedded in routine clinical care and its associated 30-day rates of major adverse cardiac events (MACE) (the composite of cardiovascular death and MI).

 

RESULTS - Among 2,296 patients, nonST-segment elevation MI prevalence was 9.8%. In median, 1-h blood samples were collected 65 min after the 0-h blood draw. Overall, 94% of patients were managed without protocol violations, and 98% of patients triaged toward rule-out did not require additional cardiac investigations including high-sensitivity cardiac troponin T measurements at later time points or coronary computed tomography angiography in the ED. Median ED stay was 2 h and 30 min. The ESC 0/1-h algorithm triaged 62% of patients toward rule-out, and 71% of all patients underwent outpatient management. Proportion of patients with 30-day MACE were 0.2% (95% confidence interval: 03% to 0.5%) in the rule-out group and 0.1% (95% confidence interval: 0% to 0.2%) in outpatients. Very low MACE rates were confirmed in multiple subgroups, including early presenters.

 

CONCLUSIONS - These real-world data document the excellent applicability, short time to ED discharge, and low rate of 30-day MACE associated with the routine clinical use of the ESC 0/1-h algorithm for the management of patients presenting with acute chest discomfort to the ED.