Abstract

Recommended Article

Assessment of the coronary calcification by optical coherence tomography A Survey on Coronary Atherosclerotic Plaque Tissue Characterization in Intravascular Optical Coherence Tomography Impact of low tissue backscattering by optical coherence tomography on endothelial function after drug-eluting stent implantation Device specificity of vascular healing following implantation of bioresorbable vascular scaffolds and bioabsorbable polymer metallic drug-eluting stents in human coronary arteries: the ESTROFA OCT BVS vs. BP-DES study Angiography Alone Versus Angiography Plus Optical Coherence Tomography to Guide Percutaneous Coronary Intervention Outcomes From the Pan-London PCI Cohort Clinical Impact of OCT Findings During PCI: The CLI-OPCI II Study Optical Coherence Tomography Findings in Patients With Coronary Stent Thrombosis: A Report of the PRESTIGE Consortium (Prevention of Late Stent Thrombosis by an Interdisciplinary Global European Effort) Histopathological validation of optical coherence tomography findings of the coronary arteries

Clinical Trial2017 Nov 15;120(10):1772-1779

JOURNAL:Am J Cardiol. Article Link

Intracoronary Optical Coherence Tomography-Derived Virtual Fractional Flow Reserve for the Assessment of Coronary Artery Disease

Seike F, Uetani T, Nishimura K et al. Keywords: Optical Coherence Tomography-Derived Virtual Fractional Flow Reserve

ABSTRACT


Fractional flow reserve (FFR) is widely used for the assessment of myocardial ischemia. Optical coherence tomography (OCT) provides accurate visualization of coronary artery morphology. The aim of this study was to investigate the relation between FFR and OCT-derived FFR. We retrospectively analyzed 31 lesions (25 left anterior descending arteries, 2 left circumflex arteries, and 4 right coronary arteries) in 31 patients with moderate-to-severe coronary stenosis, who underwent OCT and FFR measurements simultaneously. OCT-derived FFR was calculated by the original algorithm, which was calculated using the following equation based on fluid dynamics: ΔP = FV + SV2, where V is the flow velocity, F is the coefficient of pressure loss because of viscous friction (Poiseuille resistance), and S is the coefficient of local pressure loss because of abrupt enhancement (flow separation). Mean values of % diameter stenosis by quantitative coronary angiography and FFR were 55.2 ± 14.0% and 0.70 ± 0.14, respectively. OCT-derived FFR showed a stronger linear correlation with FFR measurements (r = 0.89, p <0.001; root mean square error = 0.062 FFR units) than quantitative coronary angiography % diameter stenosis (r = -0.65, p <0.001), OCT measurements of minimum lumen area (r = 0.68, p <0.001), and % area stenosis (r = -0.70, p <0.001). OCT-derived FFR has the potential to become an alternative method for the assessment of functional myocardial ischemia, and may elucidate the relation between coronary morphology and FFR.

Copyright © 2017 Elsevier Inc. All rights reserved.