CBS 2019
CBSMD教育中心
中 文

Fractional Flow Reserve

Abstract

Recommended Article

Accuracy of Fractional Flow Reserve Derived From Coronary Angiography Experimental basis of determining maximum coronary, myocardial, and collateral blood flow by pressure measurements for assessing functional stenosis severity before and after percutaneous transluminal coronary angioplasty Anatomical plaque and vessel characteristics are associated with hemodynamic indices including fractional flow reserve and coronary flow reserve: A prospective exploratory intravascular ultrasound analysis Prognostic Implication of Functional Incomplete Revascularization and Residual Functional SYNTAX Score in Patients With Coronary Artery Disease Diagnostic performance of transluminal attenuation gradient and fractional flow reserve by coronary computed tomographic angiography (FFR(CT)) compared to invasive FFR: a sub-group analysis from the DISCOVER-FLOW and DeFACTO studies Diagnosis of ischemia-causing coronary stenoses by noninvasive fractional flow reserve computed from coronary computed tomographic angiograms. Results from the prospective multicenter DISCOVER-FLOW Machine Learning Approaches in Cardiovascular Imaging The Utility of Contrast Medium Fractional Flow Reserve in Functional Assessment Of Coronary Disease in Daily Practice

Original Research2018 Feb;27(2):212-218.

JOURNAL:Heart Lung Circ. Article Link

The Utility of Contrast Medium Fractional Flow Reserve in Functional Assessment Of Coronary Disease in Daily Practice

Van Wyk P, Puri A, Blake J et al. Keywords: Contrast Fractional Flow Reserve

ABSTRACT



BACKGROUND - Adenosine induced hyperaemic fractional flow reserve (aFFR) is a validated predictor of clinical outcome and part of routine interventional practice. Protocol issues associated with the adenosine infusion limit the use of aFFR in clinical practice. Contrast medium induced hyperaemic FFR (cFFR) is a simpler procedure from a practical standpoint. We compared the two in a real world setting.


METHODS - We analysed 76 patients that had both cFFR and aFFR assessment of 100 angiographically indeterminate coronary stenosis. cFFR was performed with intracoronary contrast medium injections (10ml for left coronary lesions and 8ml for right coronary lesions). The diagnostic performance of cFFR was analysed and compared to the gold standard aFFR.


RESULTS - Mean cFFR was 0.87 (±0.07) and mean aFFR was 0.84 (±0.08). Bland-Altman analysis revealed a close agreement between cFFR and aFFR (0.035±0.032; 95% CI: -0.028 to 0.098) and good linear correlation (r=0.92, r2=0.86; p<0.0001). Using cFFR cut-off values of ≤0.83 in predicting an aFFR value of ≤0.80 or a cFFR value ≥0.88, predicting an aFFR value of >0.80 yielded a sensitivity of 100%, specificity of 96.1%, positive predictive value of 92.3%, negative predictive value of 100% and diagnostic accuracy of 96%. Only 24% of cFFR values were in the 0.84 to 0.87 range.


CONCLUSION - Contrast medium induced hyperaemic FFR as an initial assessment may limit the need for adenosine to when cFFR falls in the 0.84 to 0.87 range. The use of adenosine infusion potentially could have been avoided in the majority of patients in this study.


Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.