光学相关断层扫描

Abstract

Recommended Article

Coronary Artery Intraplaque Microvessels by Optical Coherence Tomography Correlate With Vulnerable Plaque and Predict Clinical Outcomes in Patients With Ischemic Angina Changes in Coronary Plaque Composition in Patients With Acute Myocardial Infarction Treated With High-Intensity Statin Therapy (IBIS-4): A Serial Optical Coherence Tomography Study Randomized Comparison Between Everolimus-Eluting Bioresorbable Scaffold and Metallic Stent: Multimodality Imaging Through 3 Years Optical Coherence Tomography–Defined Plaque Vulnerability in Relation to Functional Stenosis Severity and Microvascular Dysfunction Drug-eluting stent implantation in patients with acute coronary syndrome - the Activity of Platelets after Inhibition and Cardiovascular Events: Optical Coherence Tomography (APICE OCT) study Pancoronary Plaque Characteristics in STEMI Caused by Culprit Plaque Erosion Versus Rupture: 3-Vessel OCT Study Characteristics of stent thrombosis in bifurcation lesions analysed by optical coherence tomography Myocardial Blood Flow and Coronary Flow Reserve During 3 Years Following Bioresorbable Vascular Scaffold Versus Metallic Drug-Eluting Stent Implantation: The VANISH Trial

Original Research2018 Feb 15;253:45-49.

JOURNAL:Int J Cardiol. Article Link

Vascular response and healing profile of everolimus-eluting bioresorbable vascular scaffolds for percutaneous treatment of chronic total coronary occlusions: A one-year optical coherence tomography analysis from the GHOST-CTO registry

La Manna A, Miccichè E, Capodanno D et al. Keywords: Bioresorbable vascular scaffold; Chronic total occlusion; Optical coherence tomography; Qualitative coronary analysis

ABSTRACT


BACKGROUND - Bioresorbable vascular scaffolds (BVS) have been heralded with potential benefits that are especially desired in long lesions, including chronic total occlusions (CTOs). Procedural feasibility and mid-term outcomes of BVS in CTOs have been reported. However, there is still a paucity of data regarding the vascular and healing response to BVS in CTOs evaluated by optical coherence tomography (OCT).


METHODS - This study included prospectively 21 patients who had a CTO lesion treated with a BVS. Angiography and OCT scan were recorded at either post-implantation and 1-year follow-up. Quantitative coronary angiography and OCT analyses were performed by an independent core laboratory.


RESULTS - The angiographic analysis showed a significant increase in the percentage of in-segment diameter stenosis at 1 year (11.89±9.5% vs. 21.84±11.7%; p=0.002). The OCT analysis showed a trend (p=0.07) towards increased mean scaffold area and significant reductions in mean lumen diameter (3.1±0.36mm vs. 2.85±0.47mm; p=0.0046), mean lumen area (7.8±1.73mm2 vs. 6.76±2mm2; p=0.0082) and minimal lumen area (5.26±1.86mm2 vs. 3.56±1.52mm2; p<0.0001). Malapposition area and volume decreased from 0.26±0.17mm2 to 0.08±0.1mm2 (p=0.0003) and from 14.17±12.92mm3 to 3.99±4.46mm3 (p=0.0014), respectively. The rate of uncovered or malapposed struts, measured at the frame level, was 5.29±6.48% at 1 year.


CONCLUSIONS - In a small series of CTO patients treated with BVS implantation, OCT outcomes at 1year displayed an overall favorable vascular response and healing profile.