Comparison of Accuracy of One-Use Methods for Calculating Fractional Flow Reserve by Intravascular Optical Coherence Tomography to That Determined by the Pressure-Wire Method Diagnostic performance of stress perfusion cardiac magnetic resonance for the detection of coronary artery disease: A systematic review and meta-analysis The Utility of Contrast Medium Fractional Flow Reserve in Functional Assessment Of Coronary Disease in Daily Practice Post-stenting fractional flow reserve vs coronary angiography for optimisation of percutaneous coronary intervention: TARGET-FFR trial Clinical Outcomes and Cost-Effectiveness of Fractional Flow Reserve-Guided Percutaneous Coronary Intervention in Patients With Stable Coronary Artery Disease: Three-Year Follow-Up of the FAME 2 Trial (Fractional Flow Reserve Versus Angiography for Multivessel Evaluation) Diagnostic Accuracy of Angiography-Based Quantitative Flow Ratio Measurements for Online Assessment of Coronary Stenosis Robustness of Fractional Flow Reserve for Lesion Assessment in Non-Infarct-Related Arteries of Patients With Myocardial Infarction Physiologic Characteristics and Clinical Outcomes of Patients With Discordance Between FFR and iFR

Original Research2018 Feb;27(2):212-218.

JOURNAL:Heart Lung Circ. Article Link

The Utility of Contrast Medium Fractional Flow Reserve in Functional Assessment Of Coronary Disease in Daily Practice

Van Wyk P, Puri A, Blake J et al. Keywords: Contrast Fractional Flow Reserve

ABSTRACT


BACKGROUND Adenosine induced hyperaemic fractional flow reserve (aFFR) is a validated predictor of clinical outcome and part of routine interventional practice. Protocol issues associated with the adenosine infusion limit the use of aFFR in clinical practice. Contrast medium induced hyperaemic FFR (cFFR) is a simpler procedure from a practical standpoint. We compared the two in a real world setting.


METHODS - We analysed 76 patients that had both cFFR and aFFR assessment of 100 angiographically indeterminate coronary stenosis. cFFR was performed with intracoronary contrast medium injections (10ml for left coronary lesions and 8ml for right coronary lesions). The diagnostic performance of cFFR was analysed and compared to the gold standard aFFR.


RESULTS Mean cFFR was 0.87 (±0.07) and mean aFFR was 0.84 (±0.08). Bland-Altman analysis revealed a close agreement between cFFR and aFFR (0.035±0.032; 95% CI: -0.028 to 0.098) and good linear correlation (r=0.92, r2=0.86; p<0.0001). Using cFFR cut-off values of ≤0.83 in predicting an aFFR value of ≤0.80 or a cFFR value ≥0.88, predicting an aFFR value of >0.80 yielded a sensitivity of 100%, specificity of 96.1%, positive predictive value of 92.3%, negative predictive value of 100% and diagnostic accuracy of 96%. Only 24% of cFFR values were in the 0.84 to 0.87 range.


CONCLUSION - Contrast medium induced hyperaemic FFR as an initial assessment may limit the need for adenosine to when cFFR falls in the 0.84 to 0.87 range. The use of adenosine infusion potentially could have been avoided in the majority of patients in this study.


Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.