CBS 2019
CBSMD教育中心
中 文

旋磨术

Abstract

Recommended Article

Rotational atherectomy in the subadventitial space to allow safe and successful chronic total occlusion recanalization: Pushing the limit further Rotational atherectomy and new-generation drug-eluting stent implantation Long-term outcomes of rotational atherectomy of underexpanded stents. A single center experience Short-term and long-term clinical outcomes of rotational atherectomy in resistant chronic total occlusion Prevalence, Presentation and Treatment of 'Balloon Undilatable' Chronic Total Occlusions: Insights from a Multicenter US Registry A Meta-Analysis of Contemporary Lesion Modification Strategies During Percutaneous Coronary Intervention in 244,795 Patients From 22 Studies Radial Versus Femoral Access for Rotational Atherectomy: A UK Observational Study of 8622 Patients Rotational Atherectomy Followed by Drug-Coated Balloon Dilation for Left Main In-Stent Restenosis in the Setting of Acute Coronary Syndrome Complicated with Right Coronary Chronic Total Occlusion

Original Research2018 Oct 17. [Epub ahead of print]

JOURNAL:Catheter Cardiovasc Interv. Article Link

Effect of orbital atherectomy in calcified coronary artery lesions as assessed by optical coherence tomography

Yamamoto MH, Maehara A, Kim SS et al. Keywords: calcified coronary plaque; OCT; orbital atherectomy

ABSTRACT


OBJECTIVES We sought to assess plaque modification and stent expansion following orbital atherectomy (OA) for calcified lesions using optical coherence tomography (OCT).


BACKGROUND The efficacy of OA for treating calcified lesions is not well studied, especially using intravascular imaging in vivo.


METHODS OCT was performed preprocedure, postOA, and poststent (n = 58). Calcium modification after OA was defined as a round, concave, polished calcium surface. Calcium fracture was complete discontinuity of calcium.


RESULTS Comparing prevs postOA OCT (n = 29), calcium area was significantly decreased postOA (from 3.4 mm2 [2.4–4.7] to 2.9 mm2 [1.9–3.9], P < 0.001). Poststent percent calcium fracture (calcium fracture length/calcium length) correlated with postOA percent calcium modification (calcium modification length/calcium length) (r = 0.31, P = 0.01). Among 75 calcium fractures in 35 lesions, maximum calcium thickness at the fracture site was greater with vs without calcium modification (0.58 mm [0.50–0.66] vs 0.45 mm [0.38–0.52], P = 0.003). Final optimal stent expansion, defined as minimum stent area ≥6.1 mm2or stent expansion ≥90% (medians of this cohort) at the maximum calcium angle site, was observed in 41 lesions. Larger postOA lumen area (odds ratio 2.64; 95% CI 1.21–5.76; P = 0.02) and the presence of calcium fracture (odds ratio 6.77; 95% CI 1.25–36.6; P = 0.03) were independent predictors for optimal stent expansion.

CONCLUSIONS - Calcium modification by OA facilitates poststent calcium fracture even in thick calcium. Greater calcium modification correlated with greater calcium fracture, in turn resulting in better stent expansion.

 

© 2018 Wiley Periodicals, Inc.