Optical frequency-domain imaging findings to predict good stent expansion after rotational atherectomy for severely calcified coronary lesions Transverse partial stent ablation with rotational atherectomy for suboptimal culotte technique in left main stem bifurcation Intravascular ultrasound enhances the safety of rotational atherectomy In vivo comparison of lipid-rich plaque on near-infrared spectroscopy with histopathological analysis of coronary atherectomy specimens In-Hospital Outcomes of Chronic Total Occlusion Percutaneous Coronary Interventions in Patients With Prior Coronary Artery Bypass Graft Surgery Procedural Success and Outcomes With Increasing Use of Enabling Strategies for Chronic Total Occlusion Intervention Effect of orbital atherectomy in calcified coronary artery lesions as assessed by optical coherence tomography Rotational Atherectomy in acute STEMI with heavily calcified culprit lesion is a rule breaking solution

Original Research2018 Oct 17. [Epub ahead of print]

JOURNAL:Catheter Cardiovasc Interv. Article Link

Effect of orbital atherectomy in calcified coronary artery lesions as assessed by optical coherence tomography

Yamamoto MH, Maehara A, Kim SS et al. Keywords: calcified coronary plaque; OCT; orbital atherectomy

ABSTRACT


OBJECTIVES We sought to assess plaque modification and stent expansion following orbital atherectomy (OA) for calcified lesions using optical coherence tomography (OCT).


BACKGROUND The efficacy of OA for treating calcified lesions is not well studied, especially using intravascular imaging in vivo.


METHODS OCT was performed preprocedure, postOA, and poststent (n = 58). Calcium modification after OA was defined as a round, concave, polished calcium surface. Calcium fracture was complete discontinuity of calcium.


RESULTS Comparing prevs postOA OCT (n = 29), calcium area was significantly decreased postOA (from 3.4 mm2 [2.4–4.7] to 2.9 mm2 [1.9–3.9], P < 0.001). Poststent percent calcium fracture (calcium fracture length/calcium length) correlated with postOA percent calcium modification (calcium modification length/calcium length) (r = 0.31, P = 0.01). Among 75 calcium fractures in 35 lesions, maximum calcium thickness at the fracture site was greater with vs without calcium modification (0.58 mm [0.50–0.66] vs 0.45 mm [0.38–0.52], P = 0.003). Final optimal stent expansion, defined as minimum stent area ≥6.1 mm2or stent expansion ≥90% (medians of this cohort) at the maximum calcium angle site, was observed in 41 lesions. Larger postOA lumen area (odds ratio 2.64; 95% CI 1.21–5.76; P = 0.02) and the presence of calcium fracture (odds ratio 6.77; 95% CI 1.25–36.6; P = 0.03) were independent predictors for optimal stent expansion.

CONCLUSIONS - Calcium modification by OA facilitates poststent calcium fracture even in thick calcium. Greater calcium modification correlated with greater calcium fracture, in turn resulting in better stent expansion.

 