Wireless pulmonary artery pressure monitoring guides management to reduce decompensation in heart failure with preserved ejection fraction A Fully Magnetically Levitated Circulatory Pump for Advanced Heart Failure Rationale and design of the GUIDE-IT study: Guiding Evidence Based Therapy Using Biomarker Intensified Treatment in Heart Failure H2FPEF Score for Predicting Future Heart Failure in Stable Outpatients With Cardiovascular Risk Factors Impact of Myocardial Scar on Prognostic Implication of Secondary Mitral Regurgitation in Heart Failure Association Between Functional Impairment and Medication Burden in Adults with Heart Failure Association of the Hospital Readmissions Reduction Program With Mortality Among Medicare Beneficiaries Hospitalized for Heart Failure, Acute Myocardial Infarction, and Pneumonia When and how to use SGLT2 inhibitors in patients with HFrEF or chronic kidney disease

Clinical Trial2014 Nov;7(6):935-44.

JOURNAL:Circ Heart Fail. Article Link

Wireless pulmonary artery pressure monitoring guides management to reduce decompensation in heart failure with preserved ejection fraction

Adamson PB, Abraham WT, Bourge RC et al. Keywords: heart failure with preserved ejection fraction; hemodynamic monitoring; hospitalization

ABSTRACT


BACKGROUND - In nonrandomized, open-label studies, a transcatheter interatrial shunt device (IASD, Corvia Medical) was associated with lower pulmonary capillary wedge pressure (PCWP), fewer symptoms, and greater quality of life and exercise capacity in patients with heart failure (HF) and midrange or preserved ejection fraction (EF ≥40%). We conducted the first randomized sham-controlled trial to evaluate the IASD in HF with EF ≥40%.


METHODS - REDUCE LAP-HF I (Reduce Elevated Left Atrial Pressure in Patients With Heart Failure) was a phase 2, randomized, parallel-group, blinded multicenter trial in patients with New York Heart Association class III or ambulatory class IV HF, EF ≥40%, exercise PCWP ≥25 mm Hg, and PCWP-right atrial pressure gradient ≥5 mm Hg. Participants were randomized (1:1) to the IASD versus a sham procedure (femoral venous access with intracardiac echocardiography but no IASD placement). The participants and investigators assessing the participants during follow-up were blinded to treatment assignment. The primary effectiveness end point was exercise PCWP at 1 month. The primary safety end point was major adverse cardiac, cerebrovascular, and renal events at 1 month. PCWP during exercise was compared between treatment groups using a mixed-effects repeated measures model analysis of covariance that included data from all available stages of exercise.

RESULTS - A total of 94 patients were enrolled, of whom 44 met inclusion/exclusion criteria and were randomized to the IASD (n=22) and control (n=22) groups. Mean age was 70±9 years, and 50% were female. At 1 month, the IASD resulted in a greater reduction in PCWP compared with sham control (P=0.028 accounting for all stages of exercise). Peak PCWP decreased by 3.5±6.4 mm Hg in the treatment group versus 0.5±5.0 mm Hg in the control group (P=0.14). There were no peri-procedural or 1-month major adverse cardiac, cerebrovascular, and renal events in the IASD group and 1 event (worsening renal function) in the control group (P=1.0).

CONCLUSIONS - In patients with HF and EF ≥40%, IASD treatment reduces PCWP during exercise. Whether this mechanistic effect will translate into sustained improvements in symptoms and outcomes requires further evaluation.

CLINICAL TRIAL REGISTRATION - URL: https://clinicaltrials.gov. Unique identifier: NCT02600234.