Suture- or Plug-Based Large-Bore Arteriotomy Closure: A Pilot Randomized Controlled Trial Considerations for Optimal Device Selection in Transcatheter Aortic Valve Replacement: A Review Transcatheter Aortic Valve Replacement in Low-Risk Patients With Symptomatic Severe Bicuspid Aortic Valve Stenosis Incidence, predictors, and outcomes associated with acute kidney injury in patients undergoing transcatheter aortic valve replacement: from the BRAVO-3 randomized trial Feasibility of Coronary Access and Aortic Valve Reintervention in Low-Risk TAVR Patients 5-Year Outcomes After TAVR With Balloon-Expandable Versus Self-Expanding Valves: Results From the CHOICE Randomized Clinical Trial Reduced Leaflet Motion after Transcatheter Aortic-Valve Replacement The Year in Cardiovascular Medicine 2020: Valvular Heart Disease: Discussing the Year in Cardiovascular Medicine for 2020 in the field of valvular heart disease is Professor Helmut Baumgartner and Dr Javier Bermejo. Mark Nicholls reports

Clinical TrialVolume 13, Issue 9, May 2020

JOURNAL:JACC: Cardiovascular Interventions Article Link

5-Year Outcomes After TAVR With Balloon-Expandable Versus Self-Expanding Valves: Results From the CHOICE Randomized Clinical Trial

Mohamed Abdel-Wahab, M Landt, Franz-Josef Neumann Keywords: aortic stenosis; balloon-expandable; durability; self-expanding; TAVR

ABSTRACT


OBJECTIVES -The purpose of this study was to evaluate clinical and echocardiographic outcome data of the CHOICE (Randomized Comparison of Transcatheter Heart Valves in High Risk Patients with Severe Aortic Stenosis: Medtronic CoreValve Versus Edwards SAPIEN XT) trial at 5 years.


BACKGROUND -  The CHOICE trial was designed to compare device performance of a balloon-expandable (BE) transcatheter heart valve (THV) versus a self-expanding (SE) THV.


METHODS - The CHOICE trial is an investigator-initiated trial that randomized 241 high-risk patients with severe symptomatic aortic stenosis and an anatomy suitable for treatment with both BE and SE THVs to transfemoral transcatheter aortic valve replacement with either device. The primary endpoint was device success. Patients were followed up to 5 years, with assessment of clinical outcomes, and echocardiographic evaluation of valve function and THV durability.


RESULTS - After 5 years, there were no statistically significant differences between BE and SE valves in the cumulative incidence of death from any cause (53.4% vs. 47.6%; p = 0.38), death from cardiovascular causes (31.6% vs. 21.5%; p = 0.12), all strokes (17.5% vs. 16.5%; p = 0.73), and repeat hospitalization for heart failure (28.9% vs. 22.5%; p = 0.75). SE patients had larger prosthetic valve area (1.6 ± 0.5 cm2 vs. 1.9 ± 0.5 cm2; p = 0.02) with a lower mean transprosthetic gradient (12.2 ± 8.7 mm Hg vs. 6.9 ± 2.7 mm Hg; p = 0.001) at 5 years. No differences were observed in the rates of paravalvular regurgitation. Clinical valve thrombosis occurred in 7 BE patients (7.3%) and 1 SE patient (0.8%; p = 0.06), and moderate or severe structural valve deterioration in 6 BE patients (6.6%) and no SE patient (0%; p = 0.018). The rate of bioprosthetic valve failure was low and not significantly different between both groups (4.1% vs. 3.4%; p = 0.63).


CONCLUSIONS -  Five-year follow-up of patients in the CHOICE trial revealed clinical outcomes after transfemoral transcatheter aortic valve replacement with early-generation BE and SE valves that were not statistically significantly different, with limited statistical power. Forward flow hemodynamics were significantly better with the SE valve. Moderate or severe structural valve deterioration was uncommon but occurred more frequently with the BE valve. (A Comparison of Transcatheter Heart Valves in High Risk Patients With Severe Aortic Stenosis: The CHOICE Trial [CHOICE]; NCT01645202)