CBS 2019
CBSMD教育中心
中 文

Transcatheter Aortic Valve Replacement

Abstract

Recommended Article

Considerations for Optimal Device Selection in Transcatheter Aortic Valve Replacement: A Review Timing of intervention in asymptomatic patients with valvular heart disease 5-Year Outcomes Comparing Surgical Versus Transcatheter Aortic Valve Replacement in Patients With Chronic Kidney Disease Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Replacement: A Propensity-Matched Comparison From the FRANCE-TAVI Registry Ambulatory Electrocardiogram Monitoring in Patients Undergoing Transcatheter Aortic Valve Replacement: JACC State-of-the-Art Review Transcatheter Aortic Valve Implantation Represents an Anti-Inflammatory Therapy Via Reduction of Shear Stress-Induced, Piezo-1-Mediated Monocyte Activation Late kidney injury after transcatheter aortic valve replacement Change in Kidney Function and 2-Year Mortality After Transcatheter Aortic Valve Replacement

Original ResearchVolume 13, Issue 6, March 2020

JOURNAL:JACC Cardiovasc Interv. Article Link

Coronary Protection to Prevent Coronary Obstruction During TAVR: A Multicenter International Registry

T Palmerini, T Chakravarty, F Saia et al. Keywords: coronary obstruction; stent thrombosis; TAVR

ABSTRACT


OBJECTIVES - The aim of this study was to investigate the safety and efficacy of coronary protection by preventive coronary wiring and stenting across the coronary ostia in patients at high risk for coronary obstruction after transcatheter aortic valve replacement (TAVR).

 

BACKGROUND - Coronary obstruction following TAVR is a life-threatening complication with high procedural and short-term mortality.

 

METHODS - Data were collected retrospectively from a multicenter international registry between April 2011 and February 2019.

 

RESULTS - Among 236 patients undergoing coronary protection with preventive coronary wiring, 143 had eventually stents implanted across the coronary ostia after valve deployment. At 3-year follow-up, rates of cardiac death were 7.8% in patients receiving stents and 15.7% in those not receiving stents (adjusted hazard ratio: 0.42; 95% confidence interval: 0.14 to 1.28; p = 0.13). There were 2 definite stent thromboses (0.9%) in patients receiving stents, both occurring after TAVR in “valve-in-valve” procedures. In patients not receiving stents, there were 4 delayed coronary occlusions (DCOs) (4.3%), occurring from 5 min to 6 h after wire removal. Three cases occurred in valve-in-valve procedures and 1 in a native aortic valve procedure. Distance between the virtual transcatheter valve and the protected coronary ostia <4 mm was present in 75.0% of patients with DCO compared with 30.4% of patients without DCO (p = 0.19).

 

CONCLUSIONS - In patients undergoing TAVR at high risk for coronary obstruction, preventive stent implantation across the coronary ostia is associated with good mid-term survival rates and low rates of stent thrombosis. Patients undergoing coronary protection with wire only have a considerable risk for DCO.