CBS 2019
CBSMD教育中心
中 文

Transcatheter Aortic Valve Replacement

Abstract

Recommended Article

Transcatheter Aortic Valve Replacement: Role of Multimodality Imaging in Common and Complex Clinical Scenarios Decline in Left Ventricular Ejection Fraction During Follow-Up in Patients With Severe Aortic Stenosis Contemporary real-world outcomes of surgical aortic valve replacement in 141,905 low-risk, intermediate-risk, and high-risk patients Impact of Severe Sarcopenia on Rehospitalization and Survival One Year After a TAVR Procedure in Patients Aged 75 and Older Outcomes of procedural complications in transfemoral transcatheter aortic valve replacement Guideline Update on Indications for Transcatheter Aortic Valve Implantation Based on the 2020 American College of Cardiology/American Heart Association Guidelines for Management of Valvular Heart Disease Cardiac surgery following transcatheter aortic valve replacement Five-Year Outcomes of Transcatheter or Surgical Aortic-Valve Replacement

Original Research2020 Oct 22;S0167-5273(20)34003-1.

JOURNAL:Int J Cardiol. Article Link

Procedural and clinical outcomes of type 0 versus type 1 bicuspid aortic valve stenosis undergoing trans-catheter valve replacement with new generation devices: Insight from the BEAT international collaborative registry

Y Shima, K Miura, T Shimada et al. Keywords: severe aortic stenosis;bicuspid aortic valve; TAVR; BAV morphology

ABSTRACT

BACKGROUND Although bicuspid aortic valve (BAV) is not considered a "sweet spot" to trans-catheter aortic valve replacement (TAVR), a certain number of BAV underwent TAVR. Whether BAV phenotype affects outcomes following TAVR remains debated. We aimed at evaluating the impact of BAV phenotype on procedural and clinical outcomes after TAVR using new generation trans-catheter heart valves (THVs).


METHODS - patients included in the BEAT registry were classified according to the BAV phenotype revealed at multi-slice computed tomography (MSCT) in type 0 (no raphe) vs. type 1 (1 raphe). Primary end-point was Valve Academic Research Consortium-2 (VARC-2) device success. Secondary end-points included procedural complications, rate of permanent pacemaker implantation, clinical outcomes at 30-day and 1-year.


RESULTS - Type 0 BAV was present in 25(7.1%) cases, type 1 in 218(61.8%). Baseline characteristics were well balanced between groups. Moderate-severe aortic valve calcifications at MSCT were less frequently present in type 0 vs. type 1 (52%vs.71.1%,p = 0.05). No differences were reported for THV type, size, pre and post-dilation between groups. VARC-2 success tended to be lower in type 0 vs. type 1 BAV (72%vs86.7%;p = 0.07). Higher rate of mean transprosthetic gradient ≥20 mmHg was observed in type 0 vs. type 1 group (24%vs6%,p = 0.007). No differences were reported in the rate of post-TAVR moderate-severe aortic regurgitation and clinical outcomes between groups.


CONCLUSIONS - Our study confirms TAVR feasibility in both BAV types, however a trend toward a lower VARC-2 device success and a higher rate of mean transprosthetic gradient ≥20 mmHg was observed in type 0 vs. type 1 BAV.