CBS 2019
CBSMD教育中心
中 文

Transcatheter Aortic Valve Replacement

Abstract

Recommended Article

Cardiac Structural Changes After Transcatheter Aortic Valve Replacement: Systematic Review and Meta-Analysis of Cardiovascular Magnetic Resonance Studies Incidence and Outcomes of Surgical Bailout During TAVR : Insights From the STS/ACC TVT Registry Precision Medicine in TAVR: How to Select the Right Device for the Right Patient Temporal Trends, Characteristics, and Outcomes of Infective Endocarditis After Transcatheter Aortic Valve Replacement Determinants and Impact of Heart Failure Readmission Following Transcatheter Aortic Valve Replacement Rationale and design of a randomized clinical trial comparing safety and efficacy of Myval transcatheter heart valve versus contemporary transcatheter heart valves in patients with severe symptomatic aortic valve stenosis: the LANDMARK trial Valve‐in‐Valve for Degenerated Transcatheter Aortic Valve Replacement Versus Valve‐in‐Valve for Degenerated Surgical Aortic Bioprostheses: A 3‐Center Comparison of Hemodynamic and 1‐Year Outcome Left Ventricular Rapid Pacing Via the Valve Delivery Guidewire in Transcatheter Aortic Valve Replacement

Clinical Trial2021 Mar, 77 (9) 1149–1161

JOURNAL:J Am Coll Cardiol. Article Link

Outcomes 2 Years After Transcatheter Aortic Valve Replacement in Patients at Low Surgical Risk

MB Leon , MJ Mack, and the PARTNER 3 Investigators. Keywords: TAVR vs. SAVR; low surgical risk patients; 2-year follow-up

ABSTRACT

BACKGROUND - In low surgical risk patients with symptomatic severe aortic stenosis, the PARTNER 3 (Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis) trial demonstrated superiority of transcatheter aortic valve replacement (TAVR) versus surgery for the primary endpoint of death, stroke, or re-hospitalization at 1 year.

 

OBJECTIVES - This study determined both clinical and echocardiographic outcomes between 1 and 2 years in the PARTNER 3 trial.

 

METHODS - This study randomly assigned 1,000 patients (1:1) to transfemoral TAVR with the SAPIEN 3 valve versus surgery (mean Society of Thoracic Surgeons score: 1.9%; mean age: 73 years) with clinical and echocardiography follow-up at 30 days and at 1 and 2 years. This study assessed 2-year rates of the primary endpoint and several secondary endpoints (clinical, echocardiography, and quality-of-life measures) in this as-treated analysis.

 

RESULTS - Primary endpoint follow-up at 2 years was available in 96.5% of patients. The 2-year primary endpoint was significantly reduced after TAVR versus surgery (11.5% vs. 17.4%; hazard ratio: 0.63; 95% confidence interval: 0.45 to 0.88; p = 0.007). Differences in death and stroke favoring TAVR at 1 year were not statistically significant at 2 years (death: TAVR 2.4% vs. surgery 3.2%; p = 0.47; stroke: TAVR 2.4% vs. surgery 3.6%; p = 0.28). Valve thrombosis at 2 years was increased after TAVR (2.6%; 13 events) compared with surgery (0.7%; 3 events; p = 0.02). Disease-specific health status continued to be better after TAVR versus surgery through 2 years. Echocardiographic findings, including hemodynamic valve deterioration and bioprosthetic valve failure, were similar for TAVR and surgery at 2 years.

 

CONCLUSIONS - At 2 years, the primary endpoint remained significantly lower with TAVR versus surgery, but initial differences in death and stroke favoring TAVR were diminished and patients who underwent TAVR had increased valve thrombosis. (Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis [PARTNER 3]; NCT02675114)