CBS 2019
CBSMD教育中心
中 文

Transcatheter Aortic Valve Replacement

Abstract

Recommended Article

Relationship Between Hospital Surgical Aortic Valve Replacement Volume and Transcatheter Aortic Valve Replacement Outcomes Coronary Access After TAVR Risk of Coronary Obstruction and Feasibility of Coronary Access After Repeat Transcatheter Aortic Valve Replacement With the Self-Expanding Evolut Valve: A Computed Tomography Simulation Study Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Severe Aortic Valve Stenosis: 1-Year Results From the All-Comers NOTION Randomized Clinical Trial Informed Shared Decisions for Patients with Aortic Stenosis Transcatheter and surgical aortic valve replacement in patients with bicuspid aortic valve Coronary Protection to Prevent Coronary Obstruction During TAVR: A Multicenter International Registry

Original Research2021 Sep, 14 (18) 1995–2005

JOURNAL:J Am Coll Cardiol Intv. Article Link

5-Year Outcomes Comparing Surgical Versus Transcatheter Aortic Valve Replacement in Patients With Chronic Kidney Disease

S Garcia, RJ Cubeddu, RT Hahn et al. Keywords: chronic kidney disease; perioperative acute kidney injury; TAVR vs. SAVR; 5-year outcome; bioprosthetic valve durability

ABSTRACT

OBJECTIVES - The aim of this study was to compare 5-year cardiovascular, renal, and bioprosthetic valve durability outcomes in patients with severe aortic stenosis (AS) and chronic kidney disease (CKD) undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR).

 

BACKGROUND - Patients with severe AS and CKD undergoing TAVR or SAVR are a challenging, understudied clinical subset.

 

METHODS - Intermediate-risk patients with moderate to severe CKD (estimated glomerular filtration rate <60 mL/min/m2) from the PARTNER (Placement of Aortic Transcatheter Valve) 2A trial (patients randomly assigned to SAPIEN XT TAVR or SAVR) and SAPIEN 3 Intermediate Risk Registry were pooled. The composite primary outcome of death, stroke, rehospitalization, and new hemodialysis was evaluated using Cox regression analysis. Patients with and without perioperative acute kidney injury (AKI) were followed through 5 years. A core laboratoryadjudicated analysis of structural valve deterioration and bioprosthetic valve failure was also performed.

 

RESULTS - The study population included 1,045 TAVR patients (512 SAPIEN XT, 533 SAPIEN 3) and 479 SAVR patients. At 5 years, SAVR was better than SAPIEN XT TAVR (52.8% vs 68.0%; P = 0.04) but similar to SAPIEN 3 TAVR (52.8% vs 58.7%; P = 0.89). Perioperative AKI was more common after SAVR than TAVR (26.3% vs 10.3%; P < 0.001) and was independently associated with long-term outcomes. Compared with SAVR, bioprosthetic valve failure and stage 2 or 3 structural valve deterioration were significantly greater for SAPIEN XT TAVR (P < 0.05) but not for SAPIEN 3 TAVR.

 

CONCLUSIONS - In intermediate-risk patients with AS and CKD, SAPIEN 3 TAVR and SAVR were associated with a similar risk for the primary endpoint at 5 years. AKI was more common after SAVR than TAVR, and SAPIEN 3 valve durability was comparable with that of surgical bioprostheses.