CBS 2019
CBSMD教育中心
中 文

Scientific Library

Abstract

Recommended Article

Significantly less inappropriate shocks in ischemic patients compared to non-ischemic patients: The S-ICD experience of a high volume single-center 2017 AHA/ACC Focused Update of the 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines Eruptive Calcified Nodules as a Potential Mechanism of Acute Coronary Thrombosis and Sudden Death Impact of Optimal Medical Therapy on 10-Year Mortality After Coronary Revascularization Myocardial infarction with non-obstructive coronary arteries as compared with myocardial infarction and obstructive coronary disease: outcomes in a Medicare population Novel predictors of late lumen enlargement in distal reference segments after successful recanalization of coronary chronic total occlusion Utility and Challenges of an Early Invasive Strategy in Patients Resuscitated From Out-of-Hospital Cardiac Arrest Position paper of the EACVI and EANM on artificial intelligence applications in multimodality cardiovascular imaging using SPECT/CT, PET/CT, and cardiac CT

Original Research14 September 2021

JOURNAL:Pacing Clin Electrophysiol. Article Link

Significantly less inappropriate shocks in ischemic patients compared to non-ischemic patients: The S-ICD experience of a high volume single-center

E Oosterwerff, A Adiyaman, A Elvan et al. Keywords: S-ICD; ischemic cardiomyopathy; non-ischemic cardiomyopathy; inappropriate shocks

ABSTRACT

BACKGROUND - The subcutaneous cardioverter-defibrillator (S-ICD) continues to be preferentially used in relatively young patients, with less advanced heart disease.

 

OBJECTIVE - We, therefore, studied the short and long-term efficacy and safety of the S-ICD in subgroups of patients, which are underreported at present.

 

METHODS - A total of 218 patients between November 2010 and February 2019 undergoing S-ICD with a follow up of at least 6 months implantation were included in a prospective registry. Mean follow up was 38 months.

 

RESULTS - The most common indication for S-ICD implantation was ischemic cardiomyopathy (n = 106, 49%). Complication rate needing invasive intervention was 9% (n = 21). Appropriate shock rate in patients with an S-ICD was 3.5%/year. A total of 30 inappropriate shocks (IAS) occurred in 19 patients (8.7%; 2.7%/year). The proportion of appropriate and inappropriate shock rates in patients with different cardiomyopathies shows remarkable variances. There were significant more IAS (3.6%/year vs. 1.7%/year,p = .048) in patients with non-ischemic cardiomyopathy versus patients with ischemic cardiomyopathy. Multivariate analysis identified, besides type of cardiomyopathy, atrial fibrillation (AF) as predictor for IAS.

 

CONCLUSION - In this real-world prospective registry we analyzed S-ICD performance in the more traditional ICD patient. Patients with ischemic cardiomyopathy had significantly less inappropriate therapy compared to patients with non-ischemic cardiomyopathy and appear to be appropriate patients for this type of device.