A Randomized Study of Distal Filter Protection Versus Conventional Treatment During Percutaneous Coronary Intervention in Patients With Attenuated Plaque Identified by Intravascular Ultrasound Relationship between intravascular ultrasound guidance and clinical outcomes after drug-eluting stents: the assessment of dual antiplatelet therapy with drug-eluting stents (ADAPT-DES) study First-in-man evaluation of intravascular optical frequency domain imaging (OFDI) of Terumo: a comparison with intravascular ultrasound and quantitative coronary angiography Assessment of coronary atherosclerosis by IVUS and IVUS-based imaging modalities: progression and regression studies, tissue composition and beyond Phenomapping for Novel Classification of Heart Failure With Preserved Ejection Fraction Comparison of intravascular ultrasound guided versus angiography guided drug eluting stent implantation: a systematic review and meta-analysis Titration of Medical Therapy for Heart Failure With Reduced Ejection Fraction Surgery Does Not Improve Survival in Patients With Isolated Severe Tricuspid Regurgitation Derivation, Validation, and Prognostic Utility of a Prediction Rule for Nonresponse to Clopidogrel: The ABCD-GENE Score Temporal Trends in Inpatient Use of Intravascular Imaging Among Patients Undergoing Percutaneous Coronary Intervention in the United States

Original Research2014 Sep 1;84(3):406-13.

JOURNAL:Catheter Cardiovasc Interv. Article Link

Impact of myocardial supply area on the transstenotic hemodynamics as determined by fractional flow reserve

Shiono Y1 Kubo T, Tanaka A et al. Keywords: coronary angiography; fractional flow reserve; ischemic heart disease

ABSTRACT


OBJECTIVESThe aim of this study was to investigate the impact of myocardial area supplied by the coronary artery on fractional flow reserve (FFR).


BACKGROUND - Various factors other than the degree of epicardial stenosis influence the physiological significance of a coronary artery stenosis.

METHODS - A total of 296 coronary lesions in 217 patients were analyzed by quantitative coronary angiography and FFR. Myocardial area supplied by the coronary artery distal to the stenosis was evaluated by angiography using a modified version of the Alberta Provincial Project for Outcome Assessment in Coronary Heart Disease (APPROACH) score.

RESULTS - Percent diameter stenosis of the coronary lesion was 57 ± 15% (mean ± standard deviation). FFR <0.80 was seen in 132 (45%) lesions. FFR was significantly correlated with minimum lumen diameter (r = 0.584, P <0.001), percent diameter stenosis (r = -0.565, P <0.001), lesion length (r = -0.306, P <0.001), and myocardial supply area (r = -0.504, P <0.001). Multivariate logistic analysis demonstrated that minimum lumen diameter (odds ratio [OR] = 0.031, 95% confidence interval [CI] = 0.013-0.076, P < 0.001), lesion length (OR = 1.038, 95% CI = 1.009-1.069, P = 0.001), and myocardial supply area (OR = 1.113, 95% CI = 1.079-1.147, P <0.001) were independent determinants for FFR <0.80.

CONCLUSIONS - FFR, which is the index of physiological significance of coronary artery stenosis, is influenced by myocardial supply area distal to the stenosis as well as by its own minimal lumen diameter and lesion length.

© 2013 Wiley Periodicals, Inc.