CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Lowering systolic blood pressure to less than 120 mm Hg versus less than 140 mm Hg in patients with high cardiovascular risk with and without diabetes or previous stroke: an open-label,blinded-outcome,randomised trial Disturbed shear stress promotes atherosclerosis through TRIM21-regulated MAPK6 degradation and consequent endothelial inflammation

Clinical Trial2013 Feb;81(3):456-63.

JOURNAL:Catheter Cardiovasc Interv. Article Link

Intravascular ultrasound-guided systematic two-stent techniques for coronary bifurcation lesions and reduced late stent thrombosis

Chen SL, Ye F, Zhang JJ et al. Keywords: IVUS; coronary bifurcation lesions; two-stent technique; late stent thrombosis;

ABSTRACT


BACKGROUNDThe effects of intravascular ultrasound (IVUS)-guided complex approaches using drug-eluting stents (DES) for coronary bifurcation lesions on clinical outcomes has not yet been studied in detail.


OBJECTIVEOur objective was to analyze the difference in 1-year outcomes following two-stent techniques involving implantation of DES for coronary bifurcation lesions between IVUS-guided and angiography-guided groups.

METHODSFrom May 26, 2007 to March 24, 2010, 628 patients received two-stent techniques (324 in the IVUS-guided group and 304 angiography-guided) and were prospectively studied. We compared major adverse cardiac events (MACE, including cardiac death, stent thrombosis [ST], myocardial infarction [MI] and target lesion/vessel revascularization) at 12-months follow-up, before and after adjusting for propensity score matching.

RESULTSAt 12-months after the indexed procedure, patients in the angiography-guided group had significantly increased in-stent restenosis. Compared to the angiography-guided group, the IVUS-guided group had a significantly lower overall unadjusted ST rate (1.2% vs. 6.9%, P < 0.001), definite ST (0.6% vs. 5.3%, P < 0.001), late ST (0.6% vs. 4.3%, P = 0.003), MI (4.6% vs. 8.9%, P = 0.038) and cardiac death (0.9% vs. 3.3%, P = 0.049). By propensity score matching, 123 paired patients were matched. The late ST at 12-months follow-up was 0% in the IVUS-guided group versus 4.9% in the angiography-guided group (P = 0.029), resulting in significant differences in ST-elevation MI between the two groups (2.4% vs. 9.8%, P = 0.030).

CONCLUSIONSThe IVUS-guided two-stent technique was associated with significantly reduced late stent thrombosis, with a resultant reduction in ST-elevation MI. © 2012 Wiley Periodicals, Inc.

Copyright © 2012 Wiley Periodicals, Inc.