CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Randomized study on simple versus complex stenting of coronary artery bifurcation lesions: the Nordic bifurcation study Contemporary techniques in percutaneous coronary intervention for bifurcation lesions Treatment of Very Small De Novo Coronary Artery Disease With 2.0 mm Drug-Coated Balloons Showed 1-Year Clinical Outcome Comparable With 2.0 mm Drug-Eluting Stents Influence of Local Myocardial Damage on Index of Microcirculatory Resistance and Fractional Flow Reserve in Target and Nontarget Vascular Territories in a Porcine Microvascular Injury Model Adaptive development of concomitant secondary mitral and tricuspid regurgitation after transcatheter aortic valve replacement Drug-Coated Balloons for Coronary Artery Disease: Third Report of the International DCB Consensus Group Long-term efficacy and safety of drug-coated balloons versus drug-eluting stents for small coronary artery disease (BASKET-SMALL 2): 3-year follow-up of a randomised, non-inferiority trial Optical Coherence Tomography–Defined Plaque Vulnerability in Relation to Functional Stenosis Severity and Microvascular Dysfunction Clinical and angiographic outcomes of coronary dissection after paclitaxel-coated balloon angioplasty for small vessel coronary artery disease Drug-Coated Balloons: A Safe and Effective Alternative to Drug-Eluting Stents in Small Vessel Coronary Artery Disease

Clinical TrialVolume 11, Issue 15, August 2018

JOURNAL:JACC Cardiovasc Interv. Article Link

Sex Differences in Adenosine-Free Coronary Pressure Indexes - A CONTRAST Substudy

SV Shah, FM Zimmermann, NP Johnson et al. Keywords: contrast fractional flow reserve; fractional flow reserve; sex differences

ABSTRACT


OBJECTIVES - The goal of this study was to investigate sex differences in adenosine-free coronary pressure indexes.


BACKGROUND - Several adenosine-free coronary pressure wire indexes have been proposed to assess the functional significance of coronary artery lesions; however, there is a theoretical concern that sex differences may affect diagnostic performance because of differences in resting flow and distal myocardial mass.

METHODS - In this CONTRAST (Can Contrast Injection Better Approximate FFR Compared to Pure Resting Physiology?) substudy, contrast fractional flow reserve (cFFR), obtained during contrast-induced submaximal hyperemia, the instantaneous wave-free ratio (iFR), and distal/proximal coronary pressure ratio (Pd/Pa) were compared with fractional flow reserve (FFR) in 547 men and 216 women. Using FFR ≤0.8 as a reference, the diagnostic performance of each index was compared.

RESULTS - Men and women had similar diameter stenosis (p = 0.78), but women were less likely to have FFR ≤0.80 than men (42.5% vs. 51.5%, p = 0.04). Sensitivity was similar among cFFR, iFR, and Pd/Pa when comparing women and men, respectively (cFFR, 77.5% vs. 75.3%; p = 0.69; iFR, 84.9% vs. 79.4%; p = 0.30; Pd/Pa, 78.8% vs. 77.3%; p = 0.78). cFFR was more specific than iFR or Pd/Pa regardless of sex (cFFR, 94.3% vs. 95.8%; p = 0.56; iFR, 75.6% vs. 80.1%; p = 0.38; Pd/Pa, 80.6% vs. 78.7%; p = 0.69). By receiver-operating characteristic curve analysis, cFFR provided better diagnostic accuracy than resting indexes irrespective of sex (p ≤ 0.0001).

CONCLUSIONS - Despite the theoretical concern, the diagnostic sensitivity and specificity of cFFR, iFR, and Pd/Pa did not differ between the sexes. Irrespective of sex, cFFR provides the best diagnostic performance.