CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

The Wait for High-Sensitivity Troponin Is Over—Proceed Cautiously Impact of the US Food and Drug Administration–Approved Sex-Specific Cutoff Values for High-Sensitivity Cardiac Troponin T to Diagnose Myocardial Infarction Clinical Outcomes Following Intravascular Imaging-Guided Versus Coronary Angiography–Guided Percutaneous Coronary Intervention With Stent Implantation: A Systematic Review and Bayesian Network Meta-Analysis of 31 Studies and 17,882 Patients Good response to tolvaptan shortens hospitalization in patients with congestive heart failure Revision: prognostic impact of baseline glucose levels in acute myocardial infarction complicated by cardiogenic shock-a substudy of the IABP-SHOCK II-trial Usefulness of longitudinal reconstructed optical coherence tomography images for predicting the need for the reverse wire technique during coronary bifurcation interventions Cardiac Implantable Electronic Devices in Patients With Left Ventricular Assist Systems Wearable Cardioverter-Defibrillator after Myocardial Infarction Use of Risk Assessment Tools to Guide Decision-Making in the Primary Prevention of Atherosclerotic Cardiovascular Disease A Special Report From the American Heart Association and American College of Cardiology What's new in the Fourth Universal Definition of Myocardial infarction?

Clinical TrialVolume 11, Issue 15, August 2018

JOURNAL:JACC Cardiovasc Interv. Article Link

Sex Differences in Adenosine-Free Coronary Pressure Indexes - A CONTRAST Substudy

SV Shah, FM Zimmermann, NP Johnson et al. Keywords: contrast fractional flow reserve; fractional flow reserve; sex differences

ABSTRACT


OBJECTIVES - The goal of this study was to investigate sex differences in adenosine-free coronary pressure indexes.


BACKGROUND - Several adenosine-free coronary pressure wire indexes have been proposed to assess the functional significance of coronary artery lesions; however, there is a theoretical concern that sex differences may affect diagnostic performance because of differences in resting flow and distal myocardial mass.

METHODS - In this CONTRAST (Can Contrast Injection Better Approximate FFR Compared to Pure Resting Physiology?) substudy, contrast fractional flow reserve (cFFR), obtained during contrast-induced submaximal hyperemia, the instantaneous wave-free ratio (iFR), and distal/proximal coronary pressure ratio (Pd/Pa) were compared with fractional flow reserve (FFR) in 547 men and 216 women. Using FFR ≤0.8 as a reference, the diagnostic performance of each index was compared.

RESULTS - Men and women had similar diameter stenosis (p = 0.78), but women were less likely to have FFR ≤0.80 than men (42.5% vs. 51.5%, p = 0.04). Sensitivity was similar among cFFR, iFR, and Pd/Pa when comparing women and men, respectively (cFFR, 77.5% vs. 75.3%; p = 0.69; iFR, 84.9% vs. 79.4%; p = 0.30; Pd/Pa, 78.8% vs. 77.3%; p = 0.78). cFFR was more specific than iFR or Pd/Pa regardless of sex (cFFR, 94.3% vs. 95.8%; p = 0.56; iFR, 75.6% vs. 80.1%; p = 0.38; Pd/Pa, 80.6% vs. 78.7%; p = 0.69). By receiver-operating characteristic curve analysis, cFFR provided better diagnostic accuracy than resting indexes irrespective of sex (p ≤ 0.0001).

CONCLUSIONS - Despite the theoretical concern, the diagnostic sensitivity and specificity of cFFR, iFR, and Pd/Pa did not differ between the sexes. Irrespective of sex, cFFR provides the best diagnostic performance.