Progression of Device-Detected Subclinical Atrial Fibrillation and the Risk of Heart Failure Prognostic impact of baseline glucose levels in acute myocardial infarction complicated by cardiogenic shock-a substudy of the IABP-SHOCK II-trial Mortality Following Cardiovascular and Bleeding Events Occurring Beyond 1 Year After Coronary Stenting - A Secondary Analysis of the Dual Antiplatelet Therapy (DAPT) Study Successful Treatment of Unprotected Left Main Coronary Bifurcation Lesion Using Minimum Contrast Volume with Intravascular Ultrasound Guidance Editor's Choice- Impact of immediate multivessel percutaneous coronary intervention versus culprit lesion intervention on 1-year outcome in patients with acute myocardial infarction complicated by cardiogenic shock: Results of the randomised IABP-SHOCK II trial Cutoff Value and Long-Term Prediction of Clinical Events by FFR Measured Immediately After Implantation of a Drug-Eluting Stent in Patients With Coronary Artery Disease: 1- to 3-Year Results From the DKCRUSH VII Registry Study Improving the Use of Primary Prevention Implantable Cardioverter-Defibrillators Therapy With Validated Patient-Centric Risk Estimates Intravascular ultrasound guidance in drug-eluting stents implantation: a meta-analysis and trial sequential analysis of randomized controlled trials Intra-aortic balloon counterpulsation in acute myocardial infarction complicated by cardiogenic shock (IABP-SHOCK II): final 12 month results of a randomised, open-label trial Prognostic impact of atrial fibrillation in cardiogenic shock complicating acute myocardial infarction: a substudy of the IABP-SHOCK II trial

Clinical TrialVolume 11, Issue 8, August 2018

JOURNAL:JACC: Cardiovascular Imaging Article Link

Abnormalities in 3-Dimensional Left Ventricular Mechanics With Anthracycline Chemotherapy Are Associated With Systolic and Diastolic Dysfunction

KW Zhang, BS Finkelman, G Gulati et al. Keywords: anthracyclines; cardio-oncology; 3D echocardiography

ABSTRACT



OBJECTIVES - The objective of this study was to evaluate the changes in three-dimensional (3D) speckle-tracking echocardiography–derived measures of mechanics and their associations with systolic and diastolic dysfunction after anthracyclines.




BACKGROUND - An improved understanding of the changes in 3D cardiac mechanics with anthracyclines may provide important mechanistic insight and identify new metrics to detect cardiac dysfunction.




METHODS - A total of 142 women with breast cancer receiving doxorubicin (240 mg/m2) with or without trastuzumab underwent 3D speckle-tracking echocardiography at standardized intervals prior to, during, and annually after chemotherapy. Left ventricular ejection fraction (LVEF), global circumferential strain (GCS), global longitudinal strain (GLS), principal strain, twist, and torsion were quantified. Linear regression analyses defined the associations between clinical factors and 3D parameters. Linear regression models with cluster robust variance estimators determined the associations between 3D measures and 2-dimensional (2D) LVEF and Doppler-derived E/eʹ over time.




RESULTS - There were significant abnormalities in 3D LVEF, GCS, GLS, and principal strain post-doxorubicin compared with control subjects (p < 0.001). The 3D parameters worsened post-anthracyclines, and only partially recovered to baseline over a median of 2.1 years (interquartile range: 1 to 4 years). Higher blood pressure and body mass index were associated with worse post-anthracycline 3D GCS and GLS, respectively. All 3D measures were associated with 2D LVEF at the same visit; only 3D LVEF, GCS, GLS, and principal strain were associated with 2D LVEF at subsequent visits (p < 0.05). In exploratory analyses, 3D LVEF and GCS were associated with subsequent systolic function independent of their corresponding 2D measures. The 3D LVEF, GCS, principal strain, and twist were significantly associated with concurrent, but not subsequent, E/eʹ.



CONCLUSIONS - Anthracyclines result in early and persistent abnormalities in 3D mechanics. The 3D LVEF and strain measures are associated with concurrent and subsequent systolic dysfunction, and concurrent diastolic dysfunction. Future research is needed to define the mechanisms and clinical relevance of abnormal 3D mechanics.