CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Intravascular ultrasound-guided drug-eluting stent implantation: An updated meta-analysis of randomized control trials and observational studies Anthracycline-induced cardiotoxicity: A multicenter randomised trial comparing two strategies for guiding prevention with enalapril: The International CardioOncology Society-one trial Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial Online Quantitative Aortographic Assessment of Aortic Regurgitation After TAVR: Results of the OVAL Study Switching of Oral Anticoagulation Therapy After PCI in Patients With Atrial Fibrillation: The RE-DUAL PCI Trial Subanalysis A volumetric intravascular ultrasound comparison of early drug-eluting stent thrombosis versus restenosis Provisional versus elective two-stent strategy for unprotected true left main bifurcation lesions: Insights from a FAILS-2 sub-study The impact of intravascular ultrasound guidance during drug eluting stent implantation on angiographic outcomes American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents Colchicine Reduces Cardiovascular Events in Chronic Coronary Disease

Original Research2005 Feb 1;45(3):351-6.

JOURNAL:J Am Coll Cardiol. Article Link

Sirolimus-eluting stent implantation for unprotected left main coronary artery stenosis: comparison with bare metal stent implantation

Park SJ, Kim YH, Lee BK et al. Keywords: Sirolimus-eluting stent; unprotected left main coronary artery stenosis; bare metal stent

ABSTRACT


OBJECTIVESThis study was designed to compare the clinical and angiographic outcomes of sirolimus-eluting stent (SES) and bare metal stent (BMS) implantation for unprotected left main coronary artery (LMCA) stenosis.


BACKGROUNDThe safety and effectiveness of SES implantation for unprotected LMCA stenosis have not been ascertained.

METHODSElective SES implantation for de novo unprotected LMCA stenosis was performed in 102 consecutive patients with preserved left ventricular function from March 2003 to March 2004. Data from this group were compared to those from 121 patients treated with BMS during the preceding two years.

RESULTSCompared to the BMS group, the SES group received more direct stenting, had fewer debulking atherectomies, had a greater number of stents, had more segments stented, and underwent more bifurcation stenting. The procedural success rate was 100% for both groups. There were no incidents of death, stent thrombosis, Q-wave myocardial infarction (MI), or emergent bypass surgery during hospitalization in either group. Despite less acute gain (2.06 +/- 0.56 mm vs. 2.73 +/- 0.73 mm, p < 0.001) in the SES group, SES patients showed a lower late lumen loss (0.05 +/- 0.57 mm vs. 1.27 +/- 0.90 mm, p < 0.001) and a lower six-month angiographic restenosis rate (7.0% vs. 30.3%, p < 0.001) versus the BMS group. At 12 months, the rate of freedom from death, MI, and target lesion revascularization was 98.0 +/- 1.4% in the SES group and 81.4 +/- 3.7% in the BMS group (p = 0.0003).

CONCLUSIONSSirolimus-eluting stent implantation for unprotected LMCA stenosis appears safe with regard to acute and midterm complications and is more effective in preventing restenosis compared to BMS implantation.