CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

2021 ACC/AHA Key Data Elements and Definitions for Heart Failure: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Data Standards (Writing Committee to Develop Clinical Data Standards for Heart Failure) 2022 AHA/ACC/HFSA Guideline for the Management of Heart Failure: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines Effect of SGLT2-Inhibitors on Epicardial Adipose Tissue: A Meta-Analysis Risk of Coronary Obstruction and Feasibility of Coronary Access After Repeat Transcatheter Aortic Valve Replacement With the Self-Expanding Evolut Valve: A Computed Tomography Simulation Study Feasibility of Coronary Access and Aortic Valve Reintervention in Low-Risk TAVR Patients Mechanisms of in-stent restenosis after drug-eluting stent implantation: intravascular ultrasound analysis Association of Effective Regurgitation Orifice Area to Left Ventricular End-Diastolic Volume Ratio With Transcatheter Mitral Valve Repair OutcomesA Secondary Analysis of the COAPT Trial Comparison of newer generation self-expandable vs. balloon-expandable valves in transcatheter aortic valve implantation: the randomized SOLVE-TAVI trial Baseline Characteristics and Risk Profiles of Participants in the ISCHEMIA Randomized Clinical Trial Updated Expert Consensus Statement on Platelet Function and Genetic Testing for Guiding P2Y12 Receptor Inhibitor Treatment in Percutaneous Coronary Intervention

Original Research2005 Feb 1;45(3):351-6.

JOURNAL:J Am Coll Cardiol. Article Link

Sirolimus-eluting stent implantation for unprotected left main coronary artery stenosis: comparison with bare metal stent implantation

Park SJ, Kim YH, Lee BK et al. Keywords: Sirolimus-eluting stent; unprotected left main coronary artery stenosis; bare metal stent

ABSTRACT


OBJECTIVESThis study was designed to compare the clinical and angiographic outcomes of sirolimus-eluting stent (SES) and bare metal stent (BMS) implantation for unprotected left main coronary artery (LMCA) stenosis.


BACKGROUNDThe safety and effectiveness of SES implantation for unprotected LMCA stenosis have not been ascertained.

METHODSElective SES implantation for de novo unprotected LMCA stenosis was performed in 102 consecutive patients with preserved left ventricular function from March 2003 to March 2004. Data from this group were compared to those from 121 patients treated with BMS during the preceding two years.

RESULTSCompared to the BMS group, the SES group received more direct stenting, had fewer debulking atherectomies, had a greater number of stents, had more segments stented, and underwent more bifurcation stenting. The procedural success rate was 100% for both groups. There were no incidents of death, stent thrombosis, Q-wave myocardial infarction (MI), or emergent bypass surgery during hospitalization in either group. Despite less acute gain (2.06 +/- 0.56 mm vs. 2.73 +/- 0.73 mm, p < 0.001) in the SES group, SES patients showed a lower late lumen loss (0.05 +/- 0.57 mm vs. 1.27 +/- 0.90 mm, p < 0.001) and a lower six-month angiographic restenosis rate (7.0% vs. 30.3%, p < 0.001) versus the BMS group. At 12 months, the rate of freedom from death, MI, and target lesion revascularization was 98.0 +/- 1.4% in the SES group and 81.4 +/- 3.7% in the BMS group (p = 0.0003).

CONCLUSIONSSirolimus-eluting stent implantation for unprotected LMCA stenosis appears safe with regard to acute and midterm complications and is more effective in preventing restenosis compared to BMS implantation.