CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Position paper of the EACVI and EANM on artificial intelligence applications in multimodality cardiovascular imaging using SPECT/CT, PET/CT, and cardiac CT When high‐volume PCI operators in high‐volume hospitals move to lower volume hospitals—Do they still maintain high volume and quality of outcomes? Coronary flow velocity reserve predicts adverse prognosis in women with angina and noobstructive coronary artery disease: resultsfrom the iPOWER study Coronary Artery Calcium Is Associated with Left Ventricular Diastolic Function Independent of Myocardial Ischemia Management of Patients With NSTE-ACS: A Comparison of the Recent AHA/ACC and ESC Guidelines Impact of Coronary Lesion Complexity in Percutaneous Coronary Intervention: One-Year Outcomes From the Large, Multicentre e-Ultimaster Registry 2017 ACC/AHA/AAPA/ABC/ACPM/AGS/APhA /ASH/ ASPC/NMA/PCNA Guideline for the Prevention, Detection, Evaluation, and Management of High Blood Pressure in Adults: Executive Summary : A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines Effect of Aspirin on All-Cause Mortality in the Healthy Elderly Drug-Coated Balloon Treatment for Femoropopliteal Artery Disease: The IN.PACT Global Study De Novo In-Stent Restenosis Imaging Cohort Long-Term Outcomes of Biodegradable Versus Second-Generation Durable Polymer Drug-Eluting Stent Implantations for Myocardial Infarction

Original Research2005 Feb 1;45(3):351-6.

JOURNAL:J Am Coll Cardiol. Article Link

Sirolimus-eluting stent implantation for unprotected left main coronary artery stenosis: comparison with bare metal stent implantation

Park SJ, Kim YH, Lee BK et al. Keywords: Sirolimus-eluting stent; unprotected left main coronary artery stenosis; bare metal stent

ABSTRACT


OBJECTIVESThis study was designed to compare the clinical and angiographic outcomes of sirolimus-eluting stent (SES) and bare metal stent (BMS) implantation for unprotected left main coronary artery (LMCA) stenosis.


BACKGROUNDThe safety and effectiveness of SES implantation for unprotected LMCA stenosis have not been ascertained.

METHODSElective SES implantation for de novo unprotected LMCA stenosis was performed in 102 consecutive patients with preserved left ventricular function from March 2003 to March 2004. Data from this group were compared to those from 121 patients treated with BMS during the preceding two years.

RESULTSCompared to the BMS group, the SES group received more direct stenting, had fewer debulking atherectomies, had a greater number of stents, had more segments stented, and underwent more bifurcation stenting. The procedural success rate was 100% for both groups. There were no incidents of death, stent thrombosis, Q-wave myocardial infarction (MI), or emergent bypass surgery during hospitalization in either group. Despite less acute gain (2.06 +/- 0.56 mm vs. 2.73 +/- 0.73 mm, p < 0.001) in the SES group, SES patients showed a lower late lumen loss (0.05 +/- 0.57 mm vs. 1.27 +/- 0.90 mm, p < 0.001) and a lower six-month angiographic restenosis rate (7.0% vs. 30.3%, p < 0.001) versus the BMS group. At 12 months, the rate of freedom from death, MI, and target lesion revascularization was 98.0 +/- 1.4% in the SES group and 81.4 +/- 3.7% in the BMS group (p = 0.0003).

CONCLUSIONSSirolimus-eluting stent implantation for unprotected LMCA stenosis appears safe with regard to acute and midterm complications and is more effective in preventing restenosis compared to BMS implantation.