Prospective application of pre-defined intravascular ultrasound criteria for assessment of intermediate left main coronary artery lesions results from the multicenter LITRO study Complex PCI procedures: challenges for the interventional cardiologist 2021 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure 6-month versus 12-month or longer dual antiplatelet therapy after percutaneous coronary intervention in patients with acute coronary syndrome (SMART-DATE): a randomised, open-label, non-inferiority trial Anticoagulation After Surgical or Transcatheter Bioprosthetic Aortic Valve Replacement Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation Intravascular Ultrasound Guidance vs. Angiographic Guidance in Primary Percutaneous Coronary Intervention for ST-Segment Elevation Myocardial Infarction - Long-Term Clinical Outcomes From the CREDO-Kyoto AMI Registry Differential Impact of Heart Failure With Reduced Ejection Fraction on Men and Women Correlations between fractional flow reserve and intravascular ultrasound in patients with an ambiguous left main coronary artery stenosis Differential prognostic effect of intravascular ultrasound use according to implanted stent length

Clinical Trial2012 Oct 2;60(14):1217-22.

JOURNAL:J Am Coll Cardiol. Article Link

Clinical and angiographic outcomes of patients treated with everolimus-eluting stents or first-generation Paclitaxel-eluting stents for unprotected left main disease

Valenti R, Migliorini A, Parodi G et al. Keywords: drug-eluting stent(s); everolimus-eluting stent(s); paclitaxel-eluting stent(s)

ABSTRACT


OBJECTIVES - The goal of this study was to compare the outcomes of patients treated with everolimus-eluting stents (EES) with outcomes of patients treated with first-generation paclitaxel-eluting stents (PES) for unprotected left main disease (ULMD).


BACKGROUND - No data exist about the comparison of these 2 types of stents in ULMD.

METHODS - The primary endpoint of the study was a 1-year composite of cardiac death, nonfatal myocardial infarction, target vessel revascularization, and stroke (MACE). Secondary endpoints were 1-year target vessel failure (TVF) and 9-month angiographic in-segment restenosis >50%.

RESULTS - From 2004 to 2010, a total of 390 patients underwent ULMD percutaneous coronary intervention (224 received PES and 166 EES). The 1-year MACE rate was 21.9% in the PES group and 10.2% in the EES group (p = 0.002). TVF rate was 20.5% in the PES group and 7.8% in the EES group (p < 0.001). The in-segment restenosis rate was 5.2% in the EES group and 15.6% in the PES group (p = 0.002). EES and EuroSCORE were the only variables related to the risk of MACE. EES (odds ratio: 0.32; p = 0.007) was also independently related to the risk of restenosis.

CONCLUSIONS - EES implantation for ULMD is associated with a reduced incidence of 1-year MACE, TVF, and restenosis as compared with PES implantation.