CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Progression of Device-Detected Subclinical Atrial Fibrillation and the Risk of Heart Failure Prognostic impact of baseline glucose levels in acute myocardial infarction complicated by cardiogenic shock-a substudy of the IABP-SHOCK II-trial Mortality Following Cardiovascular and Bleeding Events Occurring Beyond 1 Year After Coronary Stenting - A Secondary Analysis of the Dual Antiplatelet Therapy (DAPT) Study Successful Treatment of Unprotected Left Main Coronary Bifurcation Lesion Using Minimum Contrast Volume with Intravascular Ultrasound Guidance Cutoff Value and Long-Term Prediction of Clinical Events by FFR Measured Immediately After Implantation of a Drug-Eluting Stent in Patients With Coronary Artery Disease: 1- to 3-Year Results From the DKCRUSH VII Registry Study Editor's Choice- Impact of immediate multivessel percutaneous coronary intervention versus culprit lesion intervention on 1-year outcome in patients with acute myocardial infarction complicated by cardiogenic shock: Results of the randomised IABP-SHOCK II trial Improving the Use of Primary Prevention Implantable Cardioverter-Defibrillators Therapy With Validated Patient-Centric Risk Estimates Intra-aortic balloon counterpulsation in acute myocardial infarction complicated by cardiogenic shock (IABP-SHOCK II): final 12 month results of a randomised, open-label trial Benefit of switching dual antiplatelet therapy after acute coronary syndrome: the TOPIC (timing of platelet inhibition after acute coronary syndrome) randomized study Prognostic impact of atrial fibrillation in cardiogenic shock complicating acute myocardial infarction: a substudy of the IABP-SHOCK II trial

Clinical Trial2014 Mar;7(3):255-63.

JOURNAL:JACC Cardiovasc Interv. Article Link

Differential prognostic impact of treatment strategy among patients with left main versus non-left main bifurcation lesions undergoing percutaneous coronary intervention: results from the COBIS (Coronary Bifurcation Stenting) Registry II

Song YB, Hahn JY, Gwon HC et al. Keywords: angioplasty; bifurcation lesions; drug-eluting stent(s); left main

ABSTRACT


OBJECTIVES - The authors sought to investigate whether the impact of treatment strategies on clinical outcomes differed between patients with left main (LM) bifurcation lesions and those with non-LM bifurcation lesions.


BACKGROUND - Few studies have considered anatomic location when comparing 1- and 2-stent strategies for bifurcation lesions.

METHODS - We compared the prognostic impact of treatment strategies on clinical outcomes in 2,044 patients with non-LM bifurcation lesions and 853 with LM bifurcation lesions. The primary outcome was target lesion failure (TLF) defined as a composite of cardiac death, myocardial infarction (MI), and target lesion revascularization.

RESULTS - The 2-stent strategy was used more frequently in the LM bifurcation group than in the non-LM bifurcation group (40.3% vs. 20.8%, p < 0.01). During a median follow-up of 36 months, the 2-stent strategy was not associated with a higher incidence of cardiac death (hazard ratio [HR]: 1.24; 95% confidence interval [CI]: 0.72 to 2.14; p = 0.44), cardiac death or MI (HR: 1.12; 95% CI: 0.58 to 2.19; p = 0.73), or TLF (HR: 1.39; 95% CI: 0.99 to 1.94; p = 0.06) in the non-LM bifurcation group. In contrast, in patients with LM bifurcation lesions, the 2-stent strategy was associated with a higher incidence of cardiac death (HR: 2.43; 95% CI: 1.05 to 5.59; p = 0.04), cardiac death or MI (HR: 2.09; 95% CI: 1.08 to 4.04; p = 0.03), as well as TLF (HR: 2.38; 95% CI: 1.60 to 3.55; p < 0.01). Significant interactions were present between treatment strategies and bifurcation lesion locations for TLF (p = 0.01).

CONCLUSIONS - The 1-stent strategy, if possible, should initially be considered the preferred approach for the treatment of coronary bifurcation lesions, especially LM bifurcation lesions. (Korean Coronary Bifurcation Stenting [COBIS] Registry II; NCT01642992).

Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.