CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Intraluminal Intensity of Blood Speckle on Intravascular Ultrasound, a Novel Predictor of Periprocedural Myocardial Injury After Coronary Stenting Coronary Catheterization and Percutaneous Coronary Intervention in China: 10-Year Results From the China PEACE-Retrospective CathPCI Study Inflammation: A New Target For CAD Treatment and Prevention Prevention, Diagnosis, and Management of Radiation-Associated Cardiac Disease: JACC Scientific Expert Panel Ranolazine in High-Risk Patients With Implanted Cardioverter-Defibrillators - The RAID Trial Acute Myocardial Infarction after Laboratory-Confirmed Influenza Infection Effect of Shorter Door-to-Balloon Times Over 20 Years on Outcomes of Patients With Anterior ST-Elevation Myocardial Infarction Undergoing Primary Percutaneous Coronary Intervention 2018 AHA/ACC/AACVPR/AAPA/ABC/ACPM/ADA/AGS/APhA/ASPC/NLA/PCNA Guideline on the Management of Blood Cholesterol: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines Prognostic significance of QRS fragmentation and correlation with infarct size in patients with anterior ST-segment elevation myocardial infarction treated with percutaneous coronary intervention: Insights from the INFUSE-AMI trial A case of influenza type a myocarditis that presents with ST elevation MI, cardiogenic shock, acute renal failure, and rhabdomyolysis and with rapid recovery after treatment with oseltamivir and intra-aortic balloon pump support

Expert Opinion2015;11 Suppl V:V102-5.

JOURNAL:EuroIntervention. Article Link

Classic crush and DK crush stenting techniques

Zhang JJ, Chen SL. Keywords: classic crush; complex bifurcation lesion; double kissing crush

ABSTRACT


Clinical data have supported the advantages of the double kissing (DK) crush technique, which consists of stenting the side branch (SB), balloon crush, first kissing, stenting the main vessel (MV) and final kissing balloon inflation, for complex coronary bifurcation lesions compared to other stenting techniques. Careful rewiring from the proximal cell of the MV stent to make sure the wire is in the true lumen of the SB stent is key to acquiring optimal angiographic results. Balloon anchoring from the MV, alternative inflation and each kissing inflation using large enough non-compliant balloons at high pressure, and the proximal optimisation technique are mandatory to improve both angiographic and clinical outcomes. Stratification of a given bifurcation lesion is recommended before decision making.


Life is long, but the key is only a few steps at the intersection. --- Qing Liu (Chinese poet)