CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Difference in basic concept of coronary bifurcation intervention between Korea and Japan. Insight from questionnaire in experts of Korean and Japanese bifurcation clubs Diagnostic accuracy of fractional flow reserve from anatomic CT angiography Gut microbiota induces high platelet response in patients with ST segment elevation myocardial infarction after ticagrelor treatment Left main coronary artery disease: importance, diagnosis, assessment, and management Left Main Bifurcation Angioplasty: Are 2 Stents One Too Many? Percutaneous coronary intervention with drug-eluting stents versus coronary artery bypass grafting in left main coronary artery disease: an individual patient data meta-analysis Predictors of Left Main Coronary Artery Disease in the ISCHEMIA Trial Nicotine promotes vascular calcification via intracellular Ca21-mediated, Nox5-induced oxidative stress, and extracellular vesicle release in vascular smooth muscle cells Individual Lesion-Level Meta-Analysis Comparing Various Doses of Intracoronary Bolus Injection of Adenosine With Intravenous Administration of Adenosine for Fractional Flow Reserve Assessment Device specificity of vascular healing following implantation of bioresorbable vascular scaffolds and bioabsorbable polymer metallic drug-eluting stents in human coronary arteries: the ESTROFA OCT BVS vs. BP-DES study

Clinical Trial2018 Aug 16.

JOURNAL:Cardiovasc Revasc Med. Article Link

A randomised trial comparing two stent sizing strategies in coronary bifurcation treatment with bioresorbable vascular scaffolds - The Absorb Bifurcation Coronary (ABC) trial

Rampat R, Mayo T, Hildick-Smith D et al. Keywords: Absorb; BVS; Bioresorbable vascular scaffold; Coronary bifurcation

ABSTRACT


BACKGROUNDLimited information is available on the use of Bioresorbable Vascular Scaffold (BVS) in bifurcations involving significant side branches. When treating bifurcation disease with metal stents, the recommendation is to choose a stent diameter based on the distal main vessel diameter. Whether this sizing strategy is applicable to BVS is currently unknown.


METHODS - We randomised 37 patients undergoing elective PCI for 'false' bifurcation disease (Medina 0,1,0; 1,0,0; 1,1,0) to receive BVS based either on proximal or distal reference diameters. Optical Frequency Domain Imaging (OFDI) measurements were performed pre BVS insertion to obtain proximal and distal reference diameters and post implantation. BVS size was chosen according to the proximal or distal reference diameter as per randomisation. Implantation was performed using the PSP technique tailored to bifurcation stenting. OFDI was repeated post implantation to confirm satisfactory expansion and apposition.

RESULTS - Baseline demographics between the two groups were similar. Patients were aged 62.8 ± 3.3 years; 76% were male. Mean side branch diameter was 2.24 ± 0.13 mm. TIMI III flow in the main vessel was achieved in all cases. Side branch occlusion occurred in 1 case (2.7%). In the distal-sizing arm, there was a greater incidence of significant malapposition (>300 μm) at the proximal end of the scaffold on OCT (2.3% versus 0.8%, p 0.023). The incidence of distal edge dissections was numerically greater in the proximal-sizing group but this was not statistically significant (31.3% vs 11.8%, p 0.17).

CONCLUSION - Both proximal and distal sizing strategies have similar procedural complication rates when using the ABSORB BVS to treat coronary bifurcations. However a proximal sizing strategy is associated with less malapposition and may be preferable.

Copyright © 2018 Elsevier Inc. All rights reserved.