CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Coronary plaque redistribution after stent implantation is determined by lipid composition: A NIRS-IVUS analysis A volumetric intravascular ultrasound comparison of early drug-eluting stent thrombosis versus restenosis Dapagliflozin for treating chronic heart failure with reduced ejection fraction Impact of epicardial adipose tissue on cardiovascular haemodynamics, metabolic profile, and prognosis in heart failure Outcomes 2 Years After Transcatheter Aortic Valve Replacement in Patients at Low Surgical Risk Rivaroxaban Plus Aspirin Versus Aspirin in Relation to Vascular Risk in the COMPASS Trial Echocardiographic Screening for Pulmonary Hypertension in Congenital Heart Disease: JACC Review Topic of the Week Comparison of the Efficacy and Safety Outcomes of Edoxaban in 8040 Women Versus 13 065 Men With Atrial Fibrillation in the ENGAGE AF-TIMI 48 Trial Percutaneous Coronary Intervention for Vulnerable Coronary Atherosclerotic Plaque Primary Prevention Trial Designs Using Coronary Imaging: A National Heart, Lung, and Blood Institute Workshop

Original Research1995 Apr 1;91(7):1959-65.

JOURNAL:Circulation. Article Link

Patterns of calcification in coronary artery disease. A statistical analysis of intravascular ultrasound and coronary angiography in 1155 lesions

Mintz GS1, Popma JJ, Pichard AD et al. Keywords: calcification; intravascular ultrasound; coronary angiography

ABSTRACT


BACKGROUNDTarget lesion calcium is a marker for significant coronary artery disease and a determinant of the success of transcatheter therapy.


METHODS AND RESULTSEleven hundred fifty-five native vessel target lesions in 1117 patients were studied by intravascular ultrasound (IVUS) and coronary angiography. The presence, magnitude, location, and distribution of IVUS calcium were analyzed and compared with the detection and classification (none/mild, moderate, and severe) by angiography. Angiography detected calcium in 440 of 1155 lesions (38%): 306 (26%) moderate calcium and 134 (12%) severe. IVUS detected lesion calcium in 841 of 1155 (73%, P < .0001 versus angiography). The mean arc of lesion calcium measured 115 +/- 110 degrees; the mean length measured 3.5 +/- 3.7 mm. Target lesion calcium was only superficial in 48%, only deep in 28%, and both superficial and deep in 24%. The mean arc of superficial calcium measured 85 +/- 108 degrees; the mean length measured 2.4 +/- 3.4 mm. Three hundred seventy-three of 1155 reference segments (32%) contained calcium (P < .0001 compared with lesion site). The mean arc of reference calcium measured 42 +/- 80 degrees; the mean length measured 1.7 +/- 3.6 mm. Only 44 (4%) had reference calcium in the absence of lesion calcium. Angiographic detection and classification of calcium depended on arcs, lengths, location, and distribution of lesion and reference segment calcium. By discriminant analysis, the classification function for predicting angiographic calcium included the arc of target lesion calcium, the arc of superficial calcium, the length of reference segment calcium, and the location of calcium within the lesion. This model correctly predicted the angiographic detection of calcification in 74.4% of lesions and the angiographic classification (none/moderate/severe) of calcium in 62.8% of lesions.

CONCLUSIONSIVUS detected calcium in > 70% of lesions, significantly more often than standard angiography. Although angiography is moderately sensitive for the detection of extensive lesion calcium (sensitivity, 60% and 85% for three- and four-quadrant calcium, respectively), it is less sensitive for the presence of milder degrees.