CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Angiographic quantitative flow ratio-guided coronary intervention (FAVOR III China): a multicentre, randomised, sham-controlled trial Randomized study on simple versus complex stenting of coronary artery bifurcation lesions: the Nordic bifurcation study Optical Coherence Tomography Predictors for Recurrent Restenosis After Paclitaxel-Coated Balloon Angioplasty for Drug-Eluting Stent Restenosis The European bifurcation club Left Main Coronary Stent study: a randomized comparison of stepwise provisional vs. systematic dual stenting strategies (EBC MAIN) In-Hospital Outcomes of Chronic Total Occlusion Percutaneous Coronary Interventions in Patients With Prior Coronary Artery Bypass Graft Surgery Comparison of the safety and efficacy of two types of drug-eluting balloons (RESTORE DEB and SeQuent® Please) in the treatment of coronary in-stent restenosis: study protocol for a randomized controlled trial (RESTORE ISR China) Comparison of new-generation drug-eluting stents versus drug-coated balloon for in-stent restenosis: a meta-analysis of randomised controlled trials Multicentre, randomized comparison of two-stent and provisional stenting techniques in patients with complex coronary bifurcation lesions: the DEFINITION II trial Sustainable Antirestenosis Effect With a Low-Dose Drug-Coated Balloon: The ILLUMENATE European Randomized Clinical Trial 2-Year Results Long-term clinical outcomes after treatment of stent restenosis with two drug-coated balloons

Original Research2011 Dec 1;108(11):1547-51.

JOURNAL:Am J Cardiol. Article Link

Histopathologic validation of the intravascular ultrasound diagnosis of calcified coronary artery nodules

Lee JB, Mintz GS, Lisauskas JB et al. Keywords: calcified nodule; features; vulnerable plaque; intravascular ultrasound

ABSTRACT


A calcified nodule is a type of potentially vulnerable plaque accounting for approximately 2% to 7% of coronary events. Because its intravascular ultrasound (IVUS) features have never been validated, the aim of this study was to assess the IVUS characteristics of calcified nodules in comparison to histopathology. IVUS was performed in 856 pathologic slices in 29 coronary arteries (11 left anterior descending, 5 left circumflex, and 13 right coronary arteries) in 18 autopsy hearts. Pathologic sections were analyzed every 2 mm; qualitative and quantitative findings of matched IVUS were analyzed. IVUS detected calcification in 285 frames; 17 (6.0%) were calcified nodules, and 268 (94.0%) were non-nodular calcium by histopathology. Two calcified nodules (11.8%) were solitary, and 15 (88.2%) were adjacent to non-nodular calcium. IVUS characteristics of calcified nodules were (1) a convex shape of the luminal surface (94.1% in calcified nodules vs 9.7% in non-nodular calcium, p <0.001), (2) a convex shape of the luminal side of calcium (100% vs 16.0%, p <0.001), (3) an irregular luminal surface (64.7% vs 11.6%, p <0.001), and (4) an irregular leading edge of calcium (88.2% vs 19.0%, p <0.001). Luminal area at the calcified nodule site was larger (6.2 ± 2.4 vs 4.3 ± 1.6 mm(2), p <0.001) and plaque burden less (57 ± 6% vs 68 ± 5%, p <0.001) than at the minimum luminal area site. In conclusion, calcified nodules have distinct IVUS features (irregular and convex luminal surface) permitting their prospective identification in vivo.