CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Anatomical plaque and vessel characteristics are associated with hemodynamic indices including fractional flow reserve and coronary flow reserve: A prospective exploratory intravascular ultrasound analysis A Novel Circulating MicroRNA for the Detection of Acute Myocarditis Nonculprit Lesion Myocardial Infarction Following Percutaneous Coronary Intervention in Patients With Acute Coronary Syndrome Optical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chronic total occlusions” (PRISON IV) trial Spontaneous Coronary Artery Dissection: JACC State-of-the-Art Review Diagnosis and Prognosis of Coronary Artery Disease with SPECT and PET Canadian spontaneous coronary artery dissection cohort study: in-hospital and 30-day outcomes How Low to Go With Glucose, Cholesterol, and Blood Pressure in Primary Prevention of CVD Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients Prognostic Implication of Thermodilution Coronary Flow Reserve in Patients Undergoing Fractional Flow Reserve Measurement

Original Research2007 Aug 15;100(4):615-20.

JOURNAL:Am J Cardiol. Article Link

Intravascular Ultrasound Parameters Associated With Stent Thrombosis After Drug-Eluting Stent Deployment

Okabe T, Mintz GS, Buch AN et al. Keywords: DES; thrombosis; IVUS; in-stent restenosis

ABSTRACT


Drug-eluting stent (DES) thrombosis (ST) can be devastating. The study aim was to evaluate intravascular ultrasound (IVUS) predictors for DES thrombosis by comparing IVUS studies after implantation in 13 patients with 14 DES thrombosis lesions with a group of controls (30 lesions in 27 patients) matched for history of chronic renal failure and type of DES. Five patients (38%) discontinued dual antiplatelet therapy at the time of ST. There were 3 in-stent restenosis lesions (21%) treated using DESs in the ST group compared with 0 in the control group (p <0.05). Compared with the control group, IVUS studies in the ST group showed a smaller minimum stent area (4.6 +/- 1.1 vs 5.6 +/- 1.7 mm(2), p = 0.0489). In the ST group, 11 of 14 stents had a minimum stent area < or =5.0 mm(2) compared with 12 of 30 in the control group (p = 0.0392). Minimum stent area in patients who stopped clopidogrel therapy and developed ST (5.30 +/- 1.15 mm(2)) tended to be larger compared with that in patients who developed ST while using clopidogrel (4.24 +/- 0.96 mm(2), p = 0.091). Within the 5-mm-long proximal and distal reference segments analyzed, the ST group had larger proximal reference maximum plaque burdens and smaller minimum lumen areas, along with a tendency toward similar findings in the distal reference segments. In conclusion, IVUS findings at the time of DES implantation in patients who subsequently developed ST showed a smaller minimum stent area (especially in patients who developed ST while using clopidogrel) and more residual disease at the stent edges.