Application of High-Sensitivity Troponin in Suspected Myocardial Infarction Effects of Aspirin for Primary Prevention in Persons with Diabetes Mellitus Randomized Comparison Between Radial and Femoral Large-Bore Access for Complex Percutaneous Coronary Intervention Post-Stroke Cardiovascular Complications and Neurogenic Cardiac Injury: JACC State-of-the-Art Review Coronary Angiography after Cardiac Arrest without ST-Segment Elevation Predicting Major Adverse Events in Patients With Acute Myocardial Infarction Management of Percutaneous Coronary Intervention Complications: Algorithms From the 2018 and 2019 Seattle Percutaneous Coronary Intervention Complications Conference European Bifurcation Club White Paper on Stenting Techniques for Patients With Bifurcated Coronary Artery Lesions Complete Revascularization with Multivessel PCI for Myocardial Infarction COVID-19 and Thrombotic or Thromboembolic Disease: Implications for Prevention, Antithrombotic Therapy, and Follow-up

Original Research2006 Jun;27(11):1305-10.

JOURNAL:Eur Heart J. Article Link

Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation

Hong MK, Mintz GS, Lee CW et al. Keywords: post-procedural final minimum stent area; IVUS; sirolimus-eluting stent; angiographic restenosis; stent length

ABSTRACT

 

AIMS - In many countries, drug-eluting stent implantation is the dominant interventional strategy. We evaluated the clinical, angiographic, procedural, and intravascular ultrasound (IVUS) predictors of angiographic restenosis after sirolimus-eluting stent (SES) implantation.

 

METHODS AND RESULTS - SES implantation was successfully performed in 550 patients with 670 native coronary lesions. Six-month follow-up angiography was performed in 449 patients (81.6%) with 543 lesions (81.1%). Clinical, angiographic, procedural, and IVUS predictors of restenosis were determined. Using multivariable logistic regression analysis, the only independent predictors of angiographic restenosis were post-procedural final minimum stent area by IVUS [odds ratio (OR)=0.586, 95% confidence interval (CI) 0.387-0.888, P=0.012] and IVUS-measured stent length (OR=1.029, 95% CI 1.002-1.056, P=0.035). Final minimum stent area by IVUS and IVUS-measured stent length that best separated restenosis from non-restenosis were 5.5 mm2 and 40 mm, respectively. Lesions with final minimum stent area<5.5 mm2 and stent length>40 mm had the highest rate of angiographic restenosis [17.7% (11/62)], P<0.001 compared with other groups.

 

CONCLUSION - Independent predictors of angiographic restenosis after SES implantation were post-procedural final minimum stent area by IVUS and IVUS-measured stent length. The angiographic restenosis rate was highest in lesions with stent area<5.5 mm2 and stent length>40 mm.