CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

A Combined Optical Coherence Tomography and Intravascular Ultrasound Study on Plaque Rupture, Plaque Erosion, and Calcified Nodule in Patients With ST-Segment Elevation Myocardial Infarction: Incidence, Morphologic Characteristics, and Outcomes After Percutaneous Coronary Intervention Negative Risk Markers for Cardiovascular Events in the Elderly Exercise Intolerance in Patients With Heart Failure: JACC State-of-the-Art Review Prognostic value of coronary artery calcium screening in subjects with and without diabetes Heart Failure With Recovered Left Ventricular Ejection Fraction: JACC Scientific Expert Panel The Use of Sex-Specific Factors in the Assessment of Women’s Cardiovascular Risk Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial Colchicine Reduces Cardiovascular Events in Chronic Coronary Disease Transcatheter versus Surgical Aortic Valve Replacement in Patients with Prior Cardiac Surgery in the Randomized PARTNER 2A Trial Early Surgery or Conservative Care for Asymptomatic Aortic Stenosis

Original Research2012 Feb 15;109(4):455-60.

JOURNAL:Am J Cardiol. Article Link

Usefulness of minimum stent cross sectional area as a predictor of angiographic restenosis after primary percutaneous coronary intervention in acute myocardial infarction (from the HORIZONS-AMI Trial IVUS substudy)

Choi SY, Maehara A, Cristea E et al. Keywords: HORIZONS-AMI trial; STEMI; angiographic restenosis; PPCI; minimum stent cross sectional area

ABSTRACT

 

HORIZONS-AMI was a prospective dual-arm randomized trial of different antithrombotic regimens and stent types in patients with ST-segment elevation myocardial infarction. A formal intravascular ultrasound (IVUS) substudy enrolled 464 patients with baseline and 13-month follow-up at 36 centers. Of them, 318 patients with 355 lesions were evaluated for this study. Angiographic restenosis occurred in 45 of 355 lesions (12.7%). Bare-metal stent use (45.5% vs 21.2%, p <0.001) and diabetes mellitus (29.5% vs 10.9%, p <0.001) were more prevalent in patients with versus without restenosis. Postprocedure IVUS minimum lumen area (5.6 mm2, 5.0 to 6.1, vs 6.7 mm2, 6.5 to 6.9, p <0.001), minimum stent area (5.7 mm2, 5.1 to 6.3, vs 6.9 mm2, 6.6 to 7.1, p <0.001), and reference average lumen area (7.7 mm2, 6.8 to 8.6, vs 9.7 mm2, 9.3 to 10.1, p <0.001) were smaller in restenotic versus nonrestenotic lesions. By multivariable analysis, minimum stent area was an independent predictor of angiographic restenosis (odds ratio 0.75, 95% confidence interval 0.61 to 0.93, p = 0.009) in addition to diabetes, bare-metal stent use, and longer stent length. Attenuated plaque behind the stent struts had a trend to predict less binary restenosis (p = 0.07). In conclusion, a smaller IVUS minimum stent area was an independent predictor of angiographic restenosis after primary percutaneous intervention in patients with ST-segment elevation myocardial infarction, similar to patients with stable coronary artery disease.