CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Anticoagulation After Surgical or Transcatheter Bioprosthetic Aortic Valve Replacement Correlations between fractional flow reserve and intravascular ultrasound in patients with an ambiguous left main coronary artery stenosis Right ventricular function and outcome in patients undergoing transcatheter aortic valve replacement Regurgitant Volume/Left Ventricular End-Diastolic Volume Ratio: Prognostic Value in Patients With Secondary Mitral Regurgitation Anticoagulation with or without Clopidogrel after Transcatheter Aortic-Valve Implantation Association of White Matter Hyperintensities and Cardiovascular Disease: The Importance of Microcirculatory Disease Long-Term All-Cause and Cause-Specific Mortality in Asymptomatic Patients With CAC ≥1,000: Results From the CAC Consortium 2019 ESC/EAS Guidelines for the management of dyslipidaemias: lipid modification to reduce cardiovascular risk: The Task Force for the management of dyslipidaemias of the European Society of Cardiology (ESC) and European Atherosclerosis Society (EAS) Prospective application of pre-defined intravascular ultrasound criteria for assessment of intermediate left main coronary artery lesions results from the multicenter LITRO study Impact of Staging Percutaneous Coronary Intervention in Left Main Artery Disease: Insights From the EXCEL Trial

Original Research2012 Feb 15;109(4):455-60.

JOURNAL:Am J Cardiol. Article Link

Usefulness of minimum stent cross sectional area as a predictor of angiographic restenosis after primary percutaneous coronary intervention in acute myocardial infarction (from the HORIZONS-AMI Trial IVUS substudy)

Choi SY, Maehara A, Cristea E et al. Keywords: HORIZONS-AMI trial; STEMI; angiographic restenosis; PPCI; minimum stent cross sectional area

ABSTRACT

 

HORIZONS-AMI was a prospective dual-arm randomized trial of different antithrombotic regimens and stent types in patients with ST-segment elevation myocardial infarction. A formal intravascular ultrasound (IVUS) substudy enrolled 464 patients with baseline and 13-month follow-up at 36 centers. Of them, 318 patients with 355 lesions were evaluated for this study. Angiographic restenosis occurred in 45 of 355 lesions (12.7%). Bare-metal stent use (45.5% vs 21.2%, p <0.001) and diabetes mellitus (29.5% vs 10.9%, p <0.001) were more prevalent in patients with versus without restenosis. Postprocedure IVUS minimum lumen area (5.6 mm2, 5.0 to 6.1, vs 6.7 mm2, 6.5 to 6.9, p <0.001), minimum stent area (5.7 mm2, 5.1 to 6.3, vs 6.9 mm2, 6.6 to 7.1, p <0.001), and reference average lumen area (7.7 mm2, 6.8 to 8.6, vs 9.7 mm2, 9.3 to 10.1, p <0.001) were smaller in restenotic versus nonrestenotic lesions. By multivariable analysis, minimum stent area was an independent predictor of angiographic restenosis (odds ratio 0.75, 95% confidence interval 0.61 to 0.93, p = 0.009) in addition to diabetes, bare-metal stent use, and longer stent length. Attenuated plaque behind the stent struts had a trend to predict less binary restenosis (p = 0.07). In conclusion, a smaller IVUS minimum stent area was an independent predictor of angiographic restenosis after primary percutaneous intervention in patients with ST-segment elevation myocardial infarction, similar to patients with stable coronary artery disease.