CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

2019 ACC/AHA/ASE Advanced Training Statement on Echocardiography (Revision of the 2003 ACC/AHA Clinical Competence Statement on Echocardiography): A Report of the ACC Competency Management Committee Regional Heterogeneity in the Coronary Vascular Response in Women With Chest Pain and Nonobstructive Coronary Artery Disease Safety and efficacy of a self-expanding versus a balloon-expandable bioprosthesis for transcatheter aortic valve replacement in patients with symptomatic severe aortic stenosis: a randomised non-inferiority trial Dual Antiplatelet Therapy Duration: Reconciling the Inconsistencies Transcatheter Aortic Valve Replacement in Low-risk Patients With Bicuspid Aortic Valve Stenosis Haemodynamic-guided management of heart failure (GUIDE-HF): a randomised controlled trial A trial to evaluate the effect of the sodium-glucose co-transporter 2 inhibitor dapagliflozin on morbidity and mortality in patients with heart failure and reduced left ventricular ejection fraction (DAPA-HF) Aspirin with or without Clopidogrel after Transcatheter Aortic-Valve Implantation Effects of Intravascular Ultrasound-Guided Versus Angiography-Guided New-Generation Drug-Eluting Stent Implantation: Meta-Analysis With Individual Patient-Level Data From 2,345 Randomized Patients Bridging the Gap Between Epigenetic and Genetic in PAH

Original Research2012 Feb 15;109(4):455-60.

JOURNAL:Am J Cardiol. Article Link

Usefulness of minimum stent cross sectional area as a predictor of angiographic restenosis after primary percutaneous coronary intervention in acute myocardial infarction (from the HORIZONS-AMI Trial IVUS substudy)

Choi SY, Maehara A, Cristea E et al. Keywords: HORIZONS-AMI trial; STEMI; angiographic restenosis; PPCI; minimum stent cross sectional area

ABSTRACT

 

HORIZONS-AMI was a prospective dual-arm randomized trial of different antithrombotic regimens and stent types in patients with ST-segment elevation myocardial infarction. A formal intravascular ultrasound (IVUS) substudy enrolled 464 patients with baseline and 13-month follow-up at 36 centers. Of them, 318 patients with 355 lesions were evaluated for this study. Angiographic restenosis occurred in 45 of 355 lesions (12.7%). Bare-metal stent use (45.5% vs 21.2%, p <0.001) and diabetes mellitus (29.5% vs 10.9%, p <0.001) were more prevalent in patients with versus without restenosis. Postprocedure IVUS minimum lumen area (5.6 mm2, 5.0 to 6.1, vs 6.7 mm2, 6.5 to 6.9, p <0.001), minimum stent area (5.7 mm2, 5.1 to 6.3, vs 6.9 mm2, 6.6 to 7.1, p <0.001), and reference average lumen area (7.7 mm2, 6.8 to 8.6, vs 9.7 mm2, 9.3 to 10.1, p <0.001) were smaller in restenotic versus nonrestenotic lesions. By multivariable analysis, minimum stent area was an independent predictor of angiographic restenosis (odds ratio 0.75, 95% confidence interval 0.61 to 0.93, p = 0.009) in addition to diabetes, bare-metal stent use, and longer stent length. Attenuated plaque behind the stent struts had a trend to predict less binary restenosis (p = 0.07). In conclusion, a smaller IVUS minimum stent area was an independent predictor of angiographic restenosis after primary percutaneous intervention in patients with ST-segment elevation myocardial infarction, similar to patients with stable coronary artery disease.