CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Coronary plaque redistribution after stent implantation is determined by lipid composition: A NIRS-IVUS analysis Serial intravascular ultrasound assessment of very late stent thrombosis after sirolimus-eluting stent placement Comparison of paclitaxel-eluting stents (Taxus) and everolimus-eluting stents (Xience) in left main coronary artery disease with 3 years follow-up (from the ESTROFA-LM registry) Increased glycated albumin and decreased esRAGE levels in serum are related to negative coronary artery remodeling in patients with type 2 diabetes: an Intravascular ultrasound study Use of clopidogrel with or without aspirin in patients taking oral anticoagulant therapy and undergoing percutaneous coronary intervention: an open-label, randomised, controlled trial Randomized study to evaluate sirolimus-eluting stents implanted at coronary bifurcation lesions Bioprosthetic valve oversizing is associated with increased risk of valve thrombosis following TAVR ACCF/AHA 2007 clinical expert consensus document on coronary artery calcium scoring by computed tomography in global cardiovascular risk assessment and in evaluation of patients with chest pain: a report of the American College of Cardiology Foundation Clinical Expert Consensus Task Force (ACCF/AHA Writing Committee to Update the 2000 Expert Consensus Document on Electron Beam Computed Tomography) developed in collaboration with the Society of Atherosclerosis Imaging and Prevention and the Society of Cardiovascular Computed Tomography Atherosclerosis — An Inflammatory Disease Metformin Lowers Body Weight But Fails to Increase Insulin Sensitivity in Chronic Heart Failure Patients without Diabetes: a Randomized, Double-Blind, Placebo-Controlled Study

Original Research2018 Oct 1;19(10):1117-1125.

JOURNAL:Eur Heart J Cardiovasc Imaging. Article Link

Serial changes in the side-branch ostial area after main-vessel stenting with kissing balloon inflation for coronary bifurcation lesions, assessed by 3D optical coherence tomography

Fujimura T, Okamura T, Tateishi H et al. Keywords: 3D optical coherence tomography; KBI; side-branch ostium

ABSTRACT

AIMS - We evaluated the influence of the jailing configuration and guidewire rewiring position in front of the side-branch(SB) ostium before kissing balloon inflation (KBI) against side-branch ostial area (SBOA) at follow-up using 3D optical coherence tomography (3D-OCT).


METHODS AND RESULTS - We retrospectively analysed the cases of the 37 consecutive patients who underwent main-vessel (MV) stenting with KBI for coronary bifurcation lesion under OCT guidance and the follow-up OCT 6-12 months. We divided the patients into two groups, considering both the jailing configuration and the rewiring position by 3D-OCT. We defined the cases that achieved both the distal rewiring and link-free carina configuration as the FCD group, and the other cases were defined as the Non-FCD group. We compared the differences in the SBOA derived by the cut-plane analysis and the number of compartments between the two groups. The median and interquartile range of serial change and percent serial change in SBOA in the FCD group were significantly larger than those in the Non-FCD group [0.43 mm2 (-0.29 to 0.91) vs. -0.65 mm2 (-1.33 to 0.34); P = 0.0136 and 9.47% (-8.37 to 27.33) vs. -13.77% (-31.64 to 10.88); P = 0.0182].


CONCLUSION - This serial OCT study demonstrated that the achievement of both the distal rewiring and link-free carina configuration may be important for the preservation of the SBOA after MV stenting with KBI for coronary bifurcation lesions.