CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Quality of Life after Everolimus-Eluting Stents or Bypass Surgery for Treatment of Left Main Disease Raising the Evidentiary Bar for Guideline Recommendations for TAVR: JACC Review Topic of the Week Canagliflozin and Renal Outcomes in Type 2 Diabetes and Nephropathy 2015 ESC Guidelines for the management of infective endocarditis: The Task Force for the Management of Infective Endocarditis of the European Society of Cardiology (ESC) Endorsed by: European Association for Cardio-Thoracic Surgery (EACTS), the European Association of Nuclear Medicine (EANM) Echocardiographic Screening for Pulmonary Hypertension in Congenital Heart Disease: JACC Review Topic of the Week Comparison of the Efficacy and Safety Outcomes of Edoxaban in 8040 Women Versus 13 065 Men With Atrial Fibrillation in the ENGAGE AF-TIMI 48 Trial Intravascular Ultrasound Parameters Associated With Stent Thrombosis After Drug-Eluting Stent Deployment The impact of intravascular ultrasound guidance during drug eluting stent implantation on angiographic outcomes Successful bailout stenting strategy against lethal coronary dissection involving left main bifurcation Contribution of stent underexpansion to recurrence after sirolimus-eluting stent implantation for in-stent restenosis

Review Article2012 Nov 22;8(7):855-65.

JOURNAL:EuroIntervention. Article Link

Comparison of intravascular ultrasound versus angiography-guided drug-eluting stent implantation: a meta-analysis of one randomised trial and ten observational studies involving 19,619 patients

Zhang JY, Farooq V, Chen SL et al. Keywords: intravascular ultrasound; drug-eluting stent; angiography; major adverse cardiac events; stent thrombosis

ABSTRACT


AIMS - The impact of intravascular ultrasound (IVUS) guided coronary drug-eluting stent(DES) implantation on clinical outcomes remains controversial. A meta-analysis of the currently available clinical trials investigating IVUS-guided DES implantation was undertaken.


METHODS AND RESULTS - We searched Medline, the Cochrane Library and other internet sources, without language or date restrictions, for published articles comparing clinical outcomes between IVUS-guided and angiography-guided DES implantation. Clinical studies with both adjusted and unadjusted data were included. Eleven studies were identified (one randomised controlled trial and 10 registries) and included in the meta-analysis with a weighted follow-up time of 20.7 ± 11.5 months. Compared with angiography guidance, IVUS-guided DES implantation was associated with a reduced incidence of death (hazard ratio [HR]: 0.59, 95% confidence interval [CI]: 0.48-0.73, p<0.001), major adverse cardiac events (HR: 0.87, 95% CI: 0.78-0.96, p=0.008) and stent thrombosis (HR: 0.58, 95% CI: 0.44-0.77, p<0.001). The incidence of myocardial infarction (HR: 0.82, 95% CI: 0.63-1.06, p=0.126), target lesion (HR: 0.90, 95% CI: 0.73-1.11, p=0.316) and target vessel (HR: 0.90, 95% CI: 0.77-1.05, p=0.195) revascularisation was comparable between the angiography and IVUS-guided arms. A repeat meta-analysis of propensity-matched studies only (six studies, n=5,300) yielded broadly similar results in terms of clinical outcomes.


CONCLUSIONS - IVUS-guided coronary DES implantationis associated with a significant reduction in death, MACE and stent thrombosis compared to angiography guidance. Appropriately powered randomised trials are necessary to confirm the findings from this meta-analysis.