CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Treatment of calcified coronary lesions with Palmaz-Schatz stents. An intravascular ultrasound study Characteristics of abnormal post-stent optical coherence tomography findings in hemodialysis patients Coronary Microcirculation Downstream Non-Infarct-Related Arteries in the Subacute Phase of Myocardial Infarction: Implications for Physiology-Guided Revascularization Comparative efficacy of two paclitaxel-coated balloons with different excipient coatings in patients with coronary in-stent restenosis: A pooled analysis of the Intracoronary Stenting and Angiographic Results: Optimizing Treatment of Drug Eluting Stent In-Stent Restenosis 3 and 4 trials Optical coherence tomography predictors of target vessel myocardial infarction after provisional stenting in patients with coronary bifurcation disease Immunotherapy of Endothelin-1 Receptor Type A for Pulmonary Arterial Hypertension Cardiotoxicity and Cardiac Monitoring Among Chemotherapy-Treated Breast Cancer Patients Anatomical Attributes of Clinically Relevant Diagonal Branches in Patients with Left Anterior Descending Coronary Artery Bifurcation Lesions Update on chronic thromboembolic pulmonary hypertension Tips of the dual-lumen microcatheter-facilitated reverse wire technique in percutaneous coronary interventions for markedly angulated bifurcated lesions

Clinical TrialFirst Online 19 June 2017

JOURNAL:Int J Cardiovasc Imaging. Article Link

Stent fracture is associated with a higher mortality in patients with type-2 diabetes treated by implantation of a second-generation drug-eluting stent

Z Ge, ZZ Liu, SL Chen et al. Keywords: type 2 diabetes; drug-eluting stent; stent fracture

ABSTRACT

Type 2 diabetes correlates with clinical events after the implantation of a second-generation drug-eluting stent (DES). The rate and prognostic value of stent fracture (SF) in patients with diabetes who underwent DES implantation remain unknown. A total of 1160 patients with- and 2251 without- diabetes, who underwent surveillance angiography at 1 year after DES implantation between June 2004 and August 2014, were prospectively studied. The primary endpoints included the incidence of SF and a composite major adverse cardiac event [MACE, including myocardial infarction (MI), cardiac death, and target-vessel revascularization (TVR)] at 1-year follow-up and at the end of follow-up for overall patients, and target lesion failure [TLF, including cardiac death, target vessel myocardial infarction (TVMI) and target lesion revascularization (TLR)] at the end of study for SF patients. In general, diabetes was associated with a higher rate of MACE at 1-year (18.4 vs. 12.9%) and end of follow-up (24.0 vs. 18.6%, all p < 0.001), compared with those in patients who did not have diabetes. The 1-year SF rate was comparable among patients with diabetes (n = 153, 13.2%) and non-diabetic patients (n = 273, 12.1%, p > 0.05). Diabetic patients with SF had a 2.6-fold increase of SF-related cardiac death at the end of study and threefold increase of re-repeat TLR when compared with non-diabetic patients with SF (5.9 vs. 2.2%, p = 0.040; 6.5 vs. 2.2%, p = 0.032), respectively. Given the fact that diabetes is correlated with increased MACE rate, SF in diabetic patients translates into differences in mortality and re-repeat TLR compared with the non-diabetic group.