CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Progression of Device-Detected Subclinical Atrial Fibrillation and the Risk of Heart Failure Prognostic impact of baseline glucose levels in acute myocardial infarction complicated by cardiogenic shock-a substudy of the IABP-SHOCK II-trial Mortality Following Cardiovascular and Bleeding Events Occurring Beyond 1 Year After Coronary Stenting - A Secondary Analysis of the Dual Antiplatelet Therapy (DAPT) Study Successful Treatment of Unprotected Left Main Coronary Bifurcation Lesion Using Minimum Contrast Volume with Intravascular Ultrasound Guidance Editor's Choice- Impact of immediate multivessel percutaneous coronary intervention versus culprit lesion intervention on 1-year outcome in patients with acute myocardial infarction complicated by cardiogenic shock: Results of the randomised IABP-SHOCK II trial Cutoff Value and Long-Term Prediction of Clinical Events by FFR Measured Immediately After Implantation of a Drug-Eluting Stent in Patients With Coronary Artery Disease: 1- to 3-Year Results From the DKCRUSH VII Registry Study Improving the Use of Primary Prevention Implantable Cardioverter-Defibrillators Therapy With Validated Patient-Centric Risk Estimates Intravascular ultrasound guidance in drug-eluting stents implantation: a meta-analysis and trial sequential analysis of randomized controlled trials Intra-aortic balloon counterpulsation in acute myocardial infarction complicated by cardiogenic shock (IABP-SHOCK II): final 12 month results of a randomised, open-label trial Prognostic impact of atrial fibrillation in cardiogenic shock complicating acute myocardial infarction: a substudy of the IABP-SHOCK II trial

Clinical TrialFirst Online 19 June 2017

JOURNAL:Int J Cardiovasc Imaging. Article Link

Stent fracture is associated with a higher mortality in patients with type-2 diabetes treated by implantation of a second-generation drug-eluting stent

Z Ge, ZZ Liu, SL Chen et al. Keywords: type 2 diabetes; drug-eluting stent; stent fracture

ABSTRACT

Type 2 diabetes correlates with clinical events after the implantation of a second-generation drug-eluting stent (DES). The rate and prognostic value of stent fracture (SF) in patients with diabetes who underwent DES implantation remain unknown. A total of 1160 patients with- and 2251 without- diabetes, who underwent surveillance angiography at 1 year after DES implantation between June 2004 and August 2014, were prospectively studied. The primary endpoints included the incidence of SF and a composite major adverse cardiac event [MACE, including myocardial infarction (MI), cardiac death, and target-vessel revascularization (TVR)] at 1-year follow-up and at the end of follow-up for overall patients, and target lesion failure [TLF, including cardiac death, target vessel myocardial infarction (TVMI) and target lesion revascularization (TLR)] at the end of study for SF patients. In general, diabetes was associated with a higher rate of MACE at 1-year (18.4 vs. 12.9%) and end of follow-up (24.0 vs. 18.6%, all p < 0.001), compared with those in patients who did not have diabetes. The 1-year SF rate was comparable among patients with diabetes (n = 153, 13.2%) and non-diabetic patients (n = 273, 12.1%, p > 0.05). Diabetic patients with SF had a 2.6-fold increase of SF-related cardiac death at the end of study and threefold increase of re-repeat TLR when compared with non-diabetic patients with SF (5.9 vs. 2.2%, p = 0.040; 6.5 vs. 2.2%, p = 0.032), respectively. Given the fact that diabetes is correlated with increased MACE rate, SF in diabetic patients translates into differences in mortality and re-repeat TLR compared with the non-diabetic group.